Table Des Matières; Do Is Common And Do Is Connected To G0 - Regin OPTIGO OP10 Mode D'emploi

Masquer les pouces Voir aussi pour OPTIGO OP10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
L
2
N
3
COM
10
NO
11
DI2
40
NC
12
DI+
41
42
G
43
13
UI+
DO
DO1
14
UI1
44
15
50
A
51
20
AI1
AO1
21
A
52
GND
AO2
22
AI2
53
54
Figure 2. Wiring example: OP10-230 with water heating, 3-position output.
Supply air control with outdoor compensation and external setpoint device.
The digital outputs are 24 V AC, G
For OP10, DO1 and DO2, the outputs can handle 12 VA. For OP10-230, DO1
and DO2, the outputs can handle 3.8 VA when using the internal transformer.
L
1
2
N
3
10
11
NC
12
DI+
DI1
13
DO1
14
UI1
15
20
A
AI1
GND
21
22
Figure 3. Wiring example: OP10-230 with 3-position actuator and room
temperature sensor (can also be used without a room temperature sensor).
The digital outputs are 24 V AC, G
is common and DO is connected to G0.
DO
For OP10, DO1 and DO2, the outputs can handle 12 VA. For OP10-230, DO1
and DO2, the outputs can handle 3.8 VA when using the internal transformer.
L 230 V AC
N
Control mode 5
Extended running
Fan indication
°C
Frost protection temp
°C
Supply air temp
°C
Outdoor temp
G0
Y1
G
Y
3
TG-R4/
4
PT1000
Figure 4. Wiring example: OP10 with 0...10 V actuator
The display menu system
The display menu system is divided into three levels, the configuration
level (10-second level), the clock and scheduler level (3-second level) and
the basic level.
The configuration level (10-second level)
This level is shown the first time the unit is connected. It is reached from
L 230 V AC
the Base Display (see the section The basic level below) by holding the
N
encoder button depressed for 10 seconds. The 10-second level holds
all the configuration menus. Note: The controller must display the Base
Display when pressing the encoder knob to reach the 10-second level.
40
41
42
43
°C
Room temp
44
50
°C
Table 2 below shows how the 10-second level is organised. When you
Supply temp
51
enter the 10-second level, you will see menu level 0. Here, you choose
52
°C
Outdoor temp
53
the control mode. You navigate through the menus and control modes
54
by turning and clicking on the encoder knob. Different menus are shown
depending on the configuration.
Table 2. Display menus in the 10-second level
Menu
level
air temp.
control
0
G
1
24 V AC
10
2
11
NO
3
12
40
DI+
41
42
13
G
UI+
43
DO
14
44
15
50
°C
Supply water temp
20
A
51
GND
21
52
A
22
53
54
Control modes
1
2
3
4
Supply
Supply
Cascade
Radiator
air temp.
control
control
contr. with
with
outd. com-
outdoor
pensation
curve
OPTIGO OP10
Output type
Output type
1
alt.
Actuating
Actuating
time
1.A
Output
Output
signal
signal
2
Neutr. zone
Neutr. zone
3
P-band
P-band
4
I-time
I-time
5
Damper
Damper
minimum
minimum
6
6
-
Function for
Function for
input UI1
input UI1
alt.
7
alt.
alt.
5
Domestic
hot water
control
Output type
Output type
-
alt.
alt.
alt.
Actuating
Actuating
time
time
time
-
Output
signal
-
-
Neutr. zone
-
-
P-band
P-band
P-band
I-time
I-time
I-time
Damper
0°C
minimum
tempera-
position
ture boost
D-factor
P-band
cascade
-
-
-
Function for
input UI1
alt.
alt.
alt.
alt.
Pump
Over-
.
exercise
heating
alt.
alt
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Optigo op10-230

Table des Matières