Instruction manual
•
Clean surface of the air conditioner with duster or semi-wet soft cloth.
Do not use chemical reagents, such as benzene, alcohol and gasoline.
•
If strainers are blocked by dust, air circulation will be impeded this will
•
If the air conditioner is used regularly the strainers needs to be cleaned
once per two weeks.
•
Pull out strainers in the direction as shown.
•
Put strainers into warm water with neutral detergent (about 40
clean up.
•
Let the strainers dry in shade place.
•
Install strainers back in the original position
POSTSEASON STORAGE
When the air conditioner is out of season or not used for long time, cor-
responding maintenance measures should be taken.
•
Drain the water as described in the drainage section
•
Wind up, and fasten power line at the back of the unit.
•
Remove exhaust pipe.
•
Set the air conditioner into a plastic bag and put it in a dry place.
•
Take out of cells of remote control and keep properly.
8
DETECTION CODES
Intelligent detection functions
Detection codes
Meaning
E1
Abnormal sense of coil pipe sensor
E2
Abnormal sense of room temperature sensor
E4
Anti-frost protection
FL
The air conditioner is in water full alarm state
C) and
o