PREPARATION FOR INSTALLATION
Before connecting the heating appliance, disconnect the
power supply using the general switch.
Class I device that can be installed in all the rooms around the
home with exception of volume 1 and 2 of the bathroom.
The heating appliance must be installed in such a way that the
switches and other control devices cannot be touched by some-
one in the bath or shower.
The heating appliance must not be installed beneath a socket. The
heating appliance must be installed at least 15 cm away from all
obstacles (shelves, curtains, furniture, etc.).
The power circuit of this appliance must include an all-pole circuit
breaking device.
Volume
3
Volume
2
60 cm
60 cm
Volume
1
60 cm
[ 9 - EN ]
15 cm MIN
A
60 cm MIN
B
The picture is the representation of a
common towel warmer.