TECHNICAL DATA
ELECTRICAL
Input voltage range
Maximum continuous output current (@25 °C)
Peak current (@25 °C)
Voltage drop
Current Output active
Consumption Output inactive
Voltage accuracy
Current accuracy
Maximum status/alarm output load
INPUT & OUTPUT CONNECTOIN
Minimum wire diameter
Bolt size
Cable lugs
FASTON CONNECTIONS
Minimum wire diameter
Faston plug
MECHANICAL
Mounting hole (Ø)
Distance between mounting holes (centre to centre)
Weight
Dimensions (H*W*L)
IP Code
Housing material
Housing colour
Cooling concept
GENERAL
Operational ambient temperature
Storage temperature
Operational air humidity
Galvanic insulation
Remote contact switch-off
PROTECTION
Overcurrent/Short circuit
Overheating, shutdown
Polarity protection
BGW40
6 ... 35 V
40 A
300 A (± 0.7 sec)
40 mV @ 40 A
3.2 mA
3.2 mA
2%
10%
100 mA
10 mm
2
M6
Cable lugs must match the cable diameter used.
1.5 mm
6.3 mm
4.2 mm
50 mm, ± 1 mm
155 g
32*72*62 mm
IP66
PU552
Black
Convection and conduction.
-10 °C ... +40 °C
-25 °C ... +85 °C
Up to 95%, non-condensing.
No
Yes
Yes (after 1 minute restart).
Above 85 °C (after 1 minute restart).
Yes, with fuse in the minus (-) line.
BGW60
60 A
60 mV @ 60 A
16 mm
2
2