OPEraTiON • Settings
Note
Ensure the day of the week and the time are set correctly
when setting the time programs.
Note
The following applies to all time programs (Pro1, Pro2,
Pro3):
If the end time is later than 23:59 h, the end time will
automatically be moved to the next day of the week.
The comfort phase is maintained past midnight and
will end on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with time
programs Pro1 and Pro2. During this time period, the appliance
heats to the set comfort temperature. Outside this specified
time period, the appliance operates in setback mode. This re-
sults in a comfort phase and a setback phase, which are repeated
daily (Pro1) or on every working day (Pro2).
Theses phases are factory-set as follows:
- 08:00 h - 22:00 h: Comfort mode
- 22:00 h - 08:00 h: Setback mode
Note
When time program Pro2 is enabled, the appliance oper-
ates at weekends exclusively in setback mode.
To adapt time programs Pro1 and Pro2 according to your needs,
proceed as follows:
f In the configuration menu, use "+" and "–" to call up the re-
quired time program.
f Press "OK".
The start time for comfort mode is displayed.
f Use "+" and "–" to set the required start time.
f Press "OK".
The end time for comfort mode is displayed.
f Use "+" and "–" to set the required end time.
f Press "OK" to save.
Time program Pro3
You can use time program Pro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time program Pro3, proceed as
follows:
f In the configuration menu, use "+" and "–" to call up time
program Pro3.
f Press "OK".
The display shows "3---".
f Press "OK".
A day of the week or a group of days is displayed.
f Use "+" and "–" to select the required day or group of days.
f Press "OK".
The start time for comfort mode is displayed.
f Use "+" and "–" to set the required start time.
© wodtke GmbH - Tübingen.
f Press "OK".
The end time for comfort mode is displayed.
f Use "+" and "–" to set the required end time.
f Press "OK".
Comfort phase "3-01" has been configured.
f To configure a further comfort phase, use "+" and "–" in time
program Pro3 to select display "3---". Proceed as describe
above.
Note
To reset the selected comfort phases, activate param-
eter P4.
f Please note that activating parameter P4 resets all
time programs (Pro1, Pro2, Pro3) to the factory set-
ting.
5.3.3 Parameter
You can call up the following parameters:
Display
Description
P1
Room temperature offset
P2
Time format
P3
Temperature display units
P4
Reset time programs (timer mode).
P5
Reset relative heating time
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a dif-
ference between displayed actual temperature I1 and the room
temperature you measure. To compensate for this difference, a
room temperature offset of ±3 °C can be set via parameter P1.
Example: The appliance indicates I1 = 21.0 °C. You have measured
a room temperature of 20.0 °C. There is a difference of 1.0 °C.
f To compensate for the difference, select an offset of P1 = -1.0.
P2: Time format
Parameter P2 is used to specify whether to display the time in
12 hour or 24 hour format.
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature is
displayed in degrees Centigrade [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
WK01_BA_190718
Options
±3 °C | ±5 °F
12 h | 24 h
°C | °F
on | off
on | off
Page 19 / 76
|