ELECTRICAL CONNECTIONS
This unit is designed to operate on a 115V/60 Hz electrical
connection Make sure that the electrical outlet is grounded
and that all safety precautions (outlined on page 1 of this
manual) are taken.
MAINTENANCE
Always turn off the power and unplug the unit before
performing maintenance procedures WARNING! Turn off
and unplug unit before servicing or clearing obstructions.
Weekly Maintenance
Keep Unit
Clean. Keep outlet air vents clear of lint/dust
debris by vacuuming out as needed
Monthly Maintenance
Clean Components
•
Using a Phillips #2 screwdriver, unscrew the four
screws connecting the bottom grill and the wire
support grill behind it Carefully lift off bottom grill
CAUTION! Watch for pinch points when handling grill;
careless handling could result in injury
•
Next, inspect blades for dirt, dust and debris. If dirty,
wipe down the blades with a damp cloth.
•
Use a vacuum or a damp cloth to remove lint and dust
from motor and grill covers. WARNING! Do not allow
water into the motor A buildup of lint and dust will
reduce the airflow and may cause the motor to
overheat and become a fire hazard.
Inspect Motor:
Look for debris or damage to motor.
Call an Authorized Service Center, or the Dri-Eaz Service
Department for help at 888-867-3235 or (360) 757-7776.
Do Not Wet Motor:
To prevent damage to motor, do not use
a hose or pressure washer to clean the unit. If motor becomes
wet, let motor dry before using again. WARNING! Keep motor
dry, a wet motor could result in personal injury.
Exterior Inspection:
Evaluate exterior components and make
sure they are properly installed If you hear any abnormal
sounds when running the unit, call an Authorized Service
Center or the Dri-Eaz Service Department at 888-867-3235 for
information on parts or repairs.
141 kinderkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: vvww.amgaircorn Email: info@amgair.corn
SPECIFICATIONS
iviodei h
Weight
Dimensions
(DxWxH)
Amp Draw
Speed
Hower
Cord Length
Fan
Construction
Wheels
Safety
Specifications are subject to change without notice.
Some values may be approximate
FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR,
or the Dri-Eaz Service Department at 888-867-3235 or (360)
757-7776
.
A
mkt
9 Geoup LUC
Air Marketing Group LLC
3/f
38 lbs (17.3 kg)
/
14.
x 2b.4 x 25 (3 ( ..3 x b4.5 x bb CM)
7.5 amps
2 speed switch
/4b VV (1.LJ hi-')
25
ft
(7.62 m)
.
8 Blades
Rotomolded shell
Plastic
ETL approved to UL standards