Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Kit W175-0638, Natural Gas to Propane Includes;
1
REGULATOR
1
#54 BURNER ORIFICE
1
PROPANE PILOT INJECTOR
1
CONVERSION DATA LABEL
Kit W175-0640, Natural Gas to Propane Includes;
1
REGULATOR
1
#52 BURNER ORIFICE
1
PROPANE PILOT INJECTOR
1
CONVERSION DATA LABEL
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved
with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.
1. Remove the safety screen, glass door and media.
2. Remove the screws that secure the media tray and burner assembly in place (screw counts vary by appliance size).
air shutter control by pushing the rod to the left.
3. Using a deep socket wrench, remove the orifice from the burner and replace with the orifice supplied.
4. Remove the two screws from the valve regulator and remove the regulator, replace with the one supplied, refer to Figure 1. Adjust
the air shutter for the burner according to the table located on the back of this page.
Figure 1
REGULATOR
5. Remove the pilot hood from the pilot assembly by pulling vertically. Use a
injector with the one supplied. Re-assemble the pilot hood onto the assembly ensuring key position for proper alignment.
6. The conversion data label must be filled out and attached adjacent to the valve.
Engage the air shutter control rod by locating the stud on the shutter with the grommet on the control rod. Push the knob to the right
7.
until the stud is totally inserted in the grommet.
appliance.
8. Turn on the gas supply. Then light the pilot to ensure the gas lines have been purged.
9. Check for gas leaks by brushing on a soap and water solution. Refer to the lighting instructions in your installation manual. Do not use
open flame. Once all systems have been checked, replace the glass media.
10. Re-install the door and safety screen.
Purge all gas lines with the glass door off.
Assure that a continuous flow is at the burner before replacing the door.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KITS FOR MODELS (C)L38 / (C)L50
These kits are for use at altitudes of 0 to 4,500 feet.
(C)L38
(C)L50
Lift this assembly up and out of the appliance.
Re-install the burner and media tray assembly. Turn on the electrical supply to the
Continued on reverse
Kit W175-0639, Propane to Natural Gas Includes;
1
REGULATOR
1
#43 BURNER ORIFICE
1
NATURAL GAS PILOT INJECTOR
1
CONVERSION DATA LABEL
Kit W175-0641, Propane to Natural Gas Includes;
1
REGULATOR
1
#39 BURNER ORIFICE
1
NATURAL GAS PILOT INJECTOR
1
CONVERSION DATA LABEL
/
" Allen key to unscrew the injector. Replace the pilot
5
32
• 1(866)820-8686
(C)L38
(C)L50
Disengage the
PILOT
HOOD
PILOT
INJECTOR
W415-1758 / A / 06.15.17
• www.napoleonfireplaces.com

Publicité

loading

Sommaire des Matières pour Napoleon (C)L38

  • Page 1 Purge all gas lines with the glass door off. Assure that a continuous flow is at the burner before replacing the door. Continued on reverse W415-1758 / A / 06.15.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...
  • Page 2 It’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustrations provided. ELECTRODE PILOT FLAME BURNER SENSOR ELECTRODE Low flame (valley) Tall flame (peak) FLAME SENSOR FLAME MUST ENVELOP UPPER 3/8” TO 1/2” OF FLAME SENSOR Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...
  • Page 3 Purgez toutes les conduites de gaz avec la porte vitrée ouverte. Assurez-vous que l’arrivée de gaz au brûleur est W415-1758 / A / 06.15.17 continue avant de remettre la porte. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfoyers.com...
  • Page 4 SONDE DE FLAMME LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DU THERMOCOUPLE ET DE LA THERMOPILE DE 3/8” À 1/2”. W415-1758 / A / 06.15.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfoyers.com...