Maintenance

E

Replacing Disposable Odor Fighting HEPA Inner Bag

WARNING: Unplug cord from electrical outlet before servicing.
BAG REMOVAL:
7
Unzip outer bag completely.
8
Pull bag cardboard collar to release bag dock door from connector. Bag dock door will hinge downward.
9
Gently pull bag cardboard collar upward out of the bag dock. Saniseal
BAG INSTALLATION:
Slide the cardboard collar completely onto bag dock door.
10
Firmly push bag dock door with both thumbs on indication point until it snaps.
11

Replacing Worn Belt

WARNING: Unplug cord from electrical outlet before servicing.
Remove the door by removing the hold down screw located on side of power head.
12
Fold door away from the power head and lift it away.
13
Remove the belt from the motor drive shaft and brush roll pulley.
14
Loop the new belt over the brush roll pulley. Place the opposite end of the belt on the motor drive shaft.
15
Replace the door by placing the bottom tab on door into slots located inside power head and pressing the
16
door closed.
Replace the hold down screw and tighten.
17
12
17

Replacing Brushroll

WARNING: Unplug cord from electrical outlet before servicing.
Your Oreck Vacuum has a brushroll that can be replaced after heavy use for improved performance.
18
Remove the baseplate by removing 5 screws. Then, remove the belt and brushroll from the housing.
19
Snap the new brushroll into place.
20
Reassemble the belt.
Reassemble the baseplate.
21
18
6
N
G
L
I
S
H
7
8
13
19
®
dust seal will close automatically.
ENFONCEZ JUSQU'À
ENTENDRE UN BRUIT
PRESIONE HASTA
CHASQUIDO DE SUJECIÓN
9
10
14
15
20
ESCUCHAR UN
11
16
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xl

Table des Matières