Maintenance and cleaning
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the
housing, impair the function of the device and harm animals, plants and the environment.
Clean only the outside of the unit with a damp cloth.
Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if minus temperatures
are expected.
How to correctly store the unit:
Drain the water remaining in the unit, in the hoses, pipes and connections as much as possi-
ble.
Thoroughly clean the unit.
Check the unit for damage and replace damaged components.
Store the unit in a dry and frost-free place.
Protect open plug connections from moisture and dirt.
Malfunction remedy
Please note the instructions for malfunction repair in the operating manual of the pump
used.
Malfunction
Pump does not start.
The pump is not delivering,
or the delivered quantity is
insufficient.
Cause
The unit is switched off.
The pump is switched off.
Power supply interrupted
The fault current protection device has
tripped.
The unit is defective.
The unit has switched off the pump due to
lack of water. The dry run indicator lamp is
lit red.
Permissible height difference of 15 m be-
tween the unit and the water fixture/wa-
ter withdrawal point is exceeded.
Incorrect pressure setting in the unit
The unit is installed against the water flow
direction.
Remedy
Switch on the unit.
Switch on the pump.
Check the electrical plug connec-
tions.
Switch off the unit and pump, and
disconnect the power plug. Then
contact the OASE service.
Remedy the cause of the lack of
water (e.g. pump malfunction).
Then press the START button on
the unit to restart the pump.
Correct the height difference.
Correct the pressure setting in the
unit.
Carry out the installation correctly.
EN
21