Quick Start
Your KT6 recorder has been preset to operate using
the most popular settings. To change the range, use
dip switches (page 6). NOTE: Dip switches can only be
changes when unit is off.
Recording Time: 7 day
Range: 0 to 100˚F
A pen(s) and a chart have already been installed for your
convenience. All you need to do to start using your KT6
recorder with the settings listed above is follow these
quick start instructions:
1. Plug in the AC adapter
2. Plug in thermocouple probe(s).
NOTE: Be sure to observe proper polarity when
connecting wires from transmitter.
3. Remove the protective pen cap from red pen and
insert on Pen Cap Holder.
Specifications
KT6 Temperature Ranges (use-selectable):
0 to +100˚F/C, 0 to +50˚F/C, 50 to +100˚F/C,
0 to +250˚F/C, 0 to +500˚F, -50 to +50˚F/C,
-50 to +50˚F/C, 0 to -100˚F/C, 0 to -50˚F/C
Temperature Accuracy:
±0.5% of full scale ±1˚C (±1.8˚F) recorder only
KT6 Temperature Sensor(s):
Bead-wire probe, type K-Thermocouple
Recording Times: 24 hour, 7 day
Display Resolution:
0.1˚F/C (-9.9 to 199.9) 1°F/°C (<-9.9 or >199.9)
Installation
Before you install your KT6 recorder, read through this
entire manual to find out about all the options that are
available to you.
Your recorder has been shipped with the following items:
1. One starter box of 0-100 7 day charts
2. One 9V alkaline battery
3. One AC adapter
4. One operation manual
5. One or Two bead-wire K-Thermocouple probes
(two for dual temperature models)
4. Press the "ON/OFF" key to turn instrument ON.
(diag, identifies the keys, see p. 4)
5. The instrument will enter a 5 second warm-up
phase, ending with the pen(s) moving to the
appropriate temperature reading(s). Under
warm-up mode the green LED flashes until ready.
When ready, LED will stay solid green.
6. Set the appropriate time by pressing the "CHART
ROTATION" key on the lower right of the dial
plate. The chart will turn clockwise while the button
is depressed. (CAUTION: Do not manually
try to turn the chart hub. Doing so may
damage instrument). Continue the rotation until
the correct hour and day on the chart is referenced
to the timing arrow. (See "Instrument Anatomy,
page 3.)
Chart Size: 6" DIA (15.2 cm)
Power Supply: 120V AC adapter with 9V battery for
back-up power (240V AC also available)
Alarms (optional): MAX/MIN, AUDIO/VISUAL
Dimensions: 7
(192mm x 192mm x 83mm)
Weight: Approx. 2.7 lbs. (1250g)
Ambient Operating Conditions: +32 to +122˚F,
(0 to +50˚C), 0 to 90%RH (non-condensing)
NOTE: Response time is slower when using battery
power source.
Place the KT6 on a flat, vibration-free surface. Be sure it
is in a vertical position and level. For best performance
and longevity, the location should be a clean
environment, free from dust and corrosive fumes. Do not
exceed temperature specifications.
Wall Mount: Keyhole slots are provided on the KT6 for
wall mounting.
Panel Mount: See the dimensional drawing for exact
panel mount cut out dimensions.
7.5" (190.5mm)
7.125" (182.2mm)
6.875" (174.6mm)
6.875" (174.6mm)
Recorder Overall
Rear Mount Opening
(Used for DIN sizes)
Front Mount
2
" x 7
" x 3
"
9/16
9/16
1/4
Figure 2.5