Introduction
Dear customer,
The construction corresponds to the low-voltage guidelines 73/23/EEC. It has also
been EMV tested and satisfies the standards of the established European and
national guidelines. The conformity has been proved, the relevant documents are in
the manufacturer's possession.
We kindly request the user to respect this operating manual in order to uphold this
condition and to ensure safe operation!
In case of questions, consult our technical information service
Germany: Tel. 0180/5 31 21 16 or 09604/40 88 47
Fax 09604/40 88 44
e-mail: tkb@conrad.de
Mon - Fri 8.00 to 18.00
Austria: Tel. 0 72 42/20 30 60 · Fax 0 72 42/20 30 66
e-mail: support@conrad.at
Mon - Thu 8.00 to 17.00
Fri. 8.00 to 14.00
Switzerland: Tel. 0848/80 12 88 · Fax 0848/80 12 89
e-mail: support@conrad.ch
Mon - Fri 8.00 to 12.00, 13.00 to 17.00
Prescribed use
The voltage converters can only be used in connection with a 12V or a 24V voltage
(according to the device model).
The voltage converters can only be used indoors, in dry surroundings. Using the volt-
age converters in motor vehicles StVZO (Motor Vehicle Regulations) is not allowed
when the vehicle is in use.
The connection of the 160W and 220W converters is made via a cigarette lighter
plug.
The 500W, 1000W and 1700W voltage converter should be firmly connected to the
voltage source with the help of the enclosed wires. The wires should not be extend-
ed.
Devices like televisions, small machines, lamps etc. which need a 230 V power sup-
ply can use the voltage converter.
14
All manuals and user guides at all-guides.com
Technical data
Specifications
12V/160W
12V/220W
12V/160W
24V/220W
Input voltage
12V DC (11,5 to 14 VDC)
24 V DC (22V to 28 V DC)
Wasted energy 380 mA
460 mA
Reception
200 mA
300 mA
approx.
Output voltage
230 V AC rms 50 Hz (rms = effective)
Voltage form
Modified sine wave (rectangular)
Operation ratio
Ouput
nominal power 160 W
220 W
Maximum
220 W
450 W
output
Fuse input
20 A
30 A
DC; FKS
yellow
green
Body, approx.
550 g
685 g
Dimensions
185 x 80 x
210 x 80 x
(L x W x H)
50 (mm)
50 (mm)
Connection
Lighter
Lighter
plug
plug
Length of the
75 cm
75 cm
connecting
cable
2
Cross section
2,5 mm
2,5 mm
of lead
Cooling
Casing
Ventilator
Overvoltage
signaling
> 14,3 V / > 28.6 V
Undervoltage
Acoustic alarm: < 11,3 V (12 V-version)
protection
Switching off: < 10,7 V (12 V-version)
12V/500W
12V/1000W
12V/1700W
24V/500W
24C/1000W
24V/1700W
750 mA
1,6 A
2,3 A
420 mA
1,0 A
1,6 A
> 80%
500 W
1000 W
1700 W
1000 W
1800 W
3000 W
2 x 30 A
4 x 30 A
6 x 30 A
green
green
green
1500 g
2400 g
3500g
235 x 130 x 335 x 150 x
335 x 195 x
70 (mm)
66 (mm)
76 (mm)
Screw
Screw
Screw
terminal
terminal
terminal
8 mm
8 mm
10 mm
100cm
100 cm
100 cm
2
2
2
10 mm
16 mm
2 x 16 mm
Ventilator
Ventilator
2xventilator
< 22,6 V (24 V-version)
< 21,4 V-version
2
23