WAVE switches automatically between day and night program. This is controlled by a photoelectric
cell positioned in the front plate of the device („Sensor"). Therefore, WAVE should not be placed in
a twilight zone. If the WAVE is placed in the dark (cabinet), it can be supplied with an external
sensor. This sensor is placed in a way that it is illuminated by aquarium light. Option: external
light sensor, art.-No: 210.41. During the night, the status LED flashes green every 2 sec.
Feeding break
Strong water movements interfere during the feeding of fish and especially feeding of invertebrates
with natural or synthetic plancton.Those movements can be interrupted by using the „PAUSE"
(break) function of WAVE. When pressing „PAUSE", all 4 pumps (powerheads and filtration pump)
are switched off for 10 minutes. It creates a phase without any currents; the animals get time to
eat. During the feeding break, the Status LED flasehes red every 2 sec.
If necessary, the break can be shortened (see „Starting").
Starting
Position the pumps at suitable places in the aquarium.
Ensure that the pumps are connected correctly.
Put the power cables of the pumps into the marked sockets at the device.
Caution: Only circulation pumps up to 100 Watt are suitable for WAVE!
Put the mains connection in.
Switch the WAVE on (I).
Feeding break:
Press the „Pause" button.
All pumps (powerheads and filtration pump) are switched off.
The red LED („Pause") blinks slowly.
After 10 minutes, WAVE switches automatically into the operation mode; all pumps start again.
It is possible to shorten the break by pressing the „Pause" button until the red LED changes back to
orange. The program changes into normal operation mode. The green LED's (pumps) light up
again.
3. Technical Data
Powerheads
Filtration pump
Power requirements/pumps
Program
„Pause"-button
Electric supply
8
3 channels
1 channel
max. 100 Watt/channel
8 day programs, 1 night program,
automatic shift through light sensor
10 minutes feeding break, automatic start
230 V / 50 Hz