Troubleshooting guide

5. Attach the duct to the exhaust outlet of the fan
PROBLEM
Secure with duct tape and make sure there
The fan seems louder than it should
is no air leak (ill. 1).
Make sure that there are no sharp bends in the duct line
(ill. 2).
For 90-degree angles, use smooth curves or break into
two smaller angles or curves (ill. 3).
NOTE
for safety and efficiency of the ventilation system,
avoid sharp angles and loose support.
The fan is not clearing the room

Limited warranty

LIGHTBULB ONLY LIMITED WARRANTY:
The 13 W, GU24 base lightbulbs included in the THEIA 90 L bathfan box are garantied one (1) year based on normal household usage. If this bulb
does not last for the time period guaranteed (based on 3 hours average usage per day / 7 days per week) return bulb, proof of purchase, register
receipt and your name and address to NAUTIKA and we will replace the bulb. This replacement is the sole remedy available, and LIABILITY FOR
DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED.
WHAT THIS BATHFAN WARRANTY COVERS:
This product is warranted against defects in workmanship and/or materials.
6. Electrical installation
The neutral wire from the power supply must be connected
HOW LONG THIS BATHFAN WARRANTY LASTS:
to the white wires of fan and light.
This warranty extends only to the original purchaser of the product and lasts for three (3) years from the date of original purchase or until the
original purchaser of the product sells or transfers the product, whichever first occurs.
The hot wire from the switch must be connected to both
black wires of fan and light.
WHAT NAUTIKA WILL DO:
The green wire from the power supply is to be connected
During the warranty period, Nautika will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole
to both green wires.
product with the same or comparable model.
WHAT THIS BATHFAN WARRANTY DOES NOT COVER:
Installation II (in existing construction)
This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse,
misuse, unauthorized repairs made or attempted. Nautika will pay return shipping charges to Nautika warehouse in warranty replacement cases.
Installing the fan body in an existing building requires an accessible
area (attic or crawl or space) above the planned installation location
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or
and existing duct and wiring.
consequential damages, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have
To install the fan body, remove the old unit, check the existing
other rights which vary from state to state and province to province. Proof of purchase is required before a warranty claim will be accepted.
ductwork and electrical wiring and follow the procedures described
in Installation I.
Printed in China for Nautika®.
If you wish to make a new opening in the existing ceiling:
All rights reserved.
– Find the best location for the ventilation purpose.
BATHROOM FAN – THEIA 90 CFM WITH 2 LIGHTS
bathroom fan with light – ClaSSiC SerieS 90 Cfm
POSSIBLE CAUSE
CFM too great
Damper not working properly or damaged
Bend in duct too close to fan discharge
Fan discharge reduced to fit smaller duct
Fan body not securely attached
Insufficient intake airflow within room
Insufficient CFM
Illustration 1
Secure with duct tape
Illustration 2
Wrong support
Illustration 3
Rights support and angle
– Make sure the chosen place has easy access to an exterior
CORRECTIVE ACTION
air outlet (wall cap or roof jack).
Be sure the CFM rating on the fan matches
– Ensure you will not have to use sharp angles or very long duct.
the size of your room
– Make sure the ductwork in the chosen place will not interfere
Check damper to ensure it is opening and
with any other existing ductwork in the building.
closing properly. If the damper has become
damaged, please call Customer Service
– Make sure there is no electrical wiring or pipes behind
the chosen place.
Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge
– After finding the optimal place, proceed with the opening.
Use recommended size ducting to reduce fan
– Ensure the support beams are strong enough to hold the unit.
noise
– Make the ductwork.
Be sure the fan is securely attached to your
– Proceed with the electrical wiring.
ceiling joists
– Follow the instructions provided for Installation I.
Be sure a door or window is slightly ajar or
opened to allow airflow. The fan is not able
to draw air out of the room without enough
Maintenance
airflow to draw from
Replacement of the light bulbs
Be sure the CFM rating on the fan matches
the requirements for your room size
– Disconnect the power.
NOTE: Using a tissue is not an accurate
– Remove the grille from the unit.
method for determining if the fan is operating
– Disconnect the light unit from connector.
properly. If the fan clears steam from the
room within approximately 15 minutes of
– Remove the bulb with care. Be careful, the bulb's glass is fragile,
don't pull too hard. Hold the base and move the lamp back
completing your shower, then the fan is
and forth in order to release it.
operating properly
– Put the new light bulb in place (it is a good thing to verify that
the new light bulb is good before installing it in the unit).
– Put the cover back in place.

Cleaning the fan

It is advisable to clean the unit periodically. Dust, molds, grease and
other dirt particles can affect the conductivity of the air in the unit.
The procedure is as follows:
– Remove the grille.
– Wash the grille with lukewarm water and use mild detergent
(e.g. liquid soap). Avoid harsh detergent or boiling water.
– Dry the grille with a kitchen towel or a cloth.
– Clean the inside of the unit with a vacuum cleaner (motor should
not be in contact with any water or chemicals and liquids).
– Dry the body with paper towel.
– Put the grille back in place
Limited warranty
This is a quality product. It was made and selected with care and Canac
offers a limited one-year warranty against any manufacturing defects
as long as it is used according to its intended use. Canac will
exchange any product that would show any such
manufacturing defects.
Made in China and packaged exclusively for Canac
P.O. Box 400, L'Ancienne-Lorette, Québec G2E 4W6
9
5

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour NAUTIKA THEIA 90 CFM

Table des Matières