Installing and setting the shock sensor
We recommend that you install the shock sensor near the door to easily
detect any intrusion.
To adjust the sensitivity of the shock sensor, turn the potentiometer aof
the sensor to the left or right. Fully rotated to the right indicates maximum
sensitivity. The LED on the sensor will flash.
Test the shock sensor 5 seconds after closing the doors and test if it is sensitive
enough.
Troubleshooting
The remote control does not work
•
Check that the battery is not discharged
•
Make sure you have paired the remote control correctly
The siren does not work
•
Check the connection between the siren and the control unit
The siren keeps sounding, and the remote control cand not stop it
•
Check the connection between the siren and the control unit
•
Check if the fuse is not burned
•
Make sure you have paired the remote control correctly
Central locking system does not work
•
Check that the motors are correctly installed
•
Check connections and the fuse
The siren sounds immediately after arming the system
•
Check the shock sensor
•
Check that the shock sensor is not too sensitive
Technical specifications
•
Power supply: 12VDC
•
Siren sound intensity 105dB
•
Communication frequency: 433MHz
•
Emission power: 10mW
7