Power Supply & Relay Wiring; Electrical Specifications; Variable Output Wiring - Aerotech RELAY PANEL CS Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RELAY PANEL CS
EN
3.3.. Power.Supply.&.Relay.Wiring
L1
EARTH
L2(N)
n.u.
3.4.. Electrical.Specifications
On/Off.Outputs:
Max voltage= 240 Vac 50/60 HZ or 28 Vdc
Max motor load = 3/4 HP (13 FLA) @ 120 Vac, 2 HP
(12 FLA) @ 240 Vac
Max resistive load current = 15 A
Tungsten light bulb = max 5 A @ 120 Vac
Variable.Outputs:.
1/2HP @ 120 Vac, 1.5 HP @ 240 Vac
3.5.. Variable.Output.Wiring.
Some relay panels are provided with a built-in variable
output board which allows using 2 variable loads. If
your panel is equipped with this board, please read
the instructions below:
The same phases must be used to power up the
variable outputs & the relay panel on 3 phase
power.
Voltage.Selector
Set the voltage selector to the corresponding power
supply : 115 or 230 Vac.
Motor.Curve
Specify the motor curve that is being used by your
variable-speed fans. A table showing all possible
motor curves is available on the back of the instal-
lation guide leaflet included with your environment
control.
2
RELAY PANEL CS rev.05
Relay Panel
Connect the panel
Power supply
85 to 250 Vac,
to a 15A Breaker !
50-60Hz
Connector for the
current sensing
plug-in card
Motor curve selector
MOTOR CURVE
1
2
3
4
EOL Selector
5
6
7
(see sec. 4.3)
8
9
10
JP3
END
YES=2-3
1
OF
2
NO=1-2
LINE
3
L1
L2/N
L2/N
L1
COM
1
2
G 1 2
Auxiliary
Auxiliary
output 1
output 2
On/Off Load
L2(N)
On/Off Load
L2(N)
Backup thermostat
(shown for illustration purposes only.
Install a sufficient number of thermostats.)
Figure 2. Power Supply & Relay Wiring
Variable-output
board (optional)
Voltage selector
230V
115/230 Vac
IN
OUT OUT
L1
IN
OUT OUT
Var.Fans Max Output=10 A
Var.Fans Max Output=10 A
Backup thermostat
(shown for illustration purposes only.
Install a sufficient number of thermostats.)
Variable outputs
EARTH
Power supply
L2(N)
115 Vac (230 Vac)
L1
Figure 3. Variable Output Board Wiring (optional)
Relay Strip
Load
Power supply
L1
Load
Power supply
L1
MOTOR CURVE
1
2
3
4
230V
5
6
7
JP3
8
END
9
OF
1
YES=2-3
10
2
LINE
NO=1-2
3
COM
L1
L2/N
L2/N
L1
IN
OUT OUT
L1
1
2
G 1 2
IN
OUT OUT
EARTH
Variable load 2
L2(N)
Power supply
L1
EARTH
Variable load 1
L2(N)
Power supply
L1