LED Behavior
Power LED
Solid Green: The Gateway is powered
Internet LED
Solid Red: No Ethernet Connection (cable disconnected
or Ethernet connection error)
Solid Amber: Ethernet Connection Detected (cable
connected and Gateway is retrieving the IP address)
Blinking Amber: Acquiring DHCP
Blinking Green: Data Exchange with TCC
Solid Green: Normal, Connected to TCC
Notes
The RedLINK Internet Gateway (RIG) pings a specific server approximately every 5 sec-
onds. The RIG waits for up to 15 seconds for a response. If there is no response, then the
ping action failed.
RIG will try different servers. If at least one can be reached, the Internet LED will be
solid green.
RIG will flash red at 1Hz if it cannot ping all servers.
RIG will work with the server it can reach, but will regularly ping servers that didn't
give a response to see if the connection is restored.
If there is a continuous ping error to the servers, RIG will release the IP and capture it
again. The Internet LED will be amber during this time.
RedLINK LED
Off: The Gateway is not connected to the RedLINK system
Green (flashing): The Gateway is connecting to the RedLINK system
Green: The Gateway is connected to the RedLINK system
Red: The RedLINK Internet Gateway is not communicating with the RedLINK system.
RedLink Internet Gateway Checklist
❑ Power Cable is Connected
❑ Green Power Light is On
❑ Ethernet Cable is Connected
❑ Internet Light is On
❑ Gateway is Connected to the RedLINK system
❑ RedLINK Green LED is On
❑ Gateway is Registered to www.mytotalconnectcomfort.com
THM6000R7001 RedLINK™ Internet Gateway
INTERNET
POWER
REDLINK
3
M36570A
33-00250EFS—03