ELECTRICAL

DOUBLE INSULATION
Double insulation is a concept in safety in electric products,
which eliminates the need for the usual three-wire grounded
power cord. All exposed metal parts are isolated from the
internal metal motor components with protecting insulation.
Double insulated products do not need to be grounded.
WARNING:
The double insulated system is intended to protect the
user from shock resulting from a break in the product's
internal wiring. Observe all normal safety precautions to
avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the product to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This is a hybrid product capable of operating on alternating
current (AC) through an extension cord or direct current (DC)
through a battery pack. If the product does not operate when
an extension cord or battery pack is installed, double-check
the power supply.
 To use alternating current, connect the product to a
power supply that is 120 volts, AC only (normal
household current), 60 Hz.
 To use direct current, install a manufacturer-
recommended 20 volt battery pack only.
NOTE: Do not operate this product on direct current
through an extension cord. Doing so would cause a
substantial voltage drop, which will cause a loss of power
and could cause the product to overheat.

SYMBOLS

The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL
SIGNAL
DANGER:
WARNING:
CAUTION:
NOTICE:
MEANING
Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation, that, if not avoided, may result in minor or moderate injury.
(Without Safety Alert Symbol) Indicates information considered important, but not related
to a potential injury (e.g. messages relating to property damage).
4 – English
EXTENSION CORDS
When using a product at a considerable distance from a
power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When using this product outdoors, use an extension
cord that is designed for outside use. This type of cord is
designated with "WA" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on product data plate)
0-2.0
2.1-3.4
Cord Length
Wire Size (A.W.G.)
25´
16
16
50´
16
16
100´
16
16
**Used on 12 gauge - 20 amp circuit
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
this product. Failure to do so can result in serious
personal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use a product with a
damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.
3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
16
16
14
16
14
14
14
12
10
14
12