APPLICATION
The ignition switch Q640 is designed to operate an ignition
transformer or a main switch between line and ignition
transformer, which ignites the pilot burner during the ligth up
sequence of the appliance.
The ignition switch Q640 is for use with the V4600/V8600
series gas controls.
SPECIFICATIONS
Model
Q640A 1002 packing quantity 100 pcs
Q640A 1010 as Q640A 1002 except TRADELINE (single
pack in a box of ten pieces).
Max. ambient temperature
Ignition switch: 70 _C
Lead wire: 105 _C
Electrical rating
1.5 A at 220 Vac inductive load.
Length of lead wire
2 x 50 cm
Srain relief
70 N minimum
INSTALLATION
IMPORTANT
The ignition switch can only be mounted at the inlet
side of the V4600/V8600 series gas controls.
Mounting (See fig. 1.)
· Insert the plunger of the ignition switch under the retainer
of the knob of the gas control.
· Fix the ignition switch with the M3.5 x 6 screw.
Wiring
The ignition switch is double insulated, therefore no earthing
is needed when the ignition switch is mounted on a low
voltage gas control.
Connect the lead wires of the ignition switch according to the
manufacturer's instructions.
Operation
The plunger of the ignition switch will be pushed down by
means of the knob during the ligth--up sequence of the
appliance.
A return spring under the plunger pushes back the plunger to
its ready position when the knob of the gas control is
released.
Checkout
Before leaving, set the appliance in operation and observe
through a complete cycle to ensure that the burner system
components function correctly.
Q640
IGNITION SWITCH
INSTRUCTION SHEET
Fig. 1.
MU1R--9176 0002R0--NE

Publicité

loading

Sommaire des Matières pour Honeywell Q640A 1002

  • Page 1 Model Q640A 1002 packing quantity 100 pcs Q640A 1010 as Q640A 1002 except TRADELINE (single pack in a box of ten pieces). Max. ambient temperature Ignition switch: 70 _C...
  • Page 2 Q640A 1002 verpakkingseenheid 100 stuks hoofdschakelaar tussen een net- en een ontstekings-- Q640A 1010 als Q640A 1002 maar dan in TRADELINE transformator die de aansteekbrander tijdens de uitvoering (afzonderlijk verpakt in een doos met tien stuks).
  • Page 3 è necessario alcun collegamento Q640A 1002 confezione da 100 pezzi a terra quando l’interruttore di accensione viene montato su Q640A 1010 come Q640A 1002 eccetto TRADELINE un dispositivo di comando del gas a bassa tensione. (confezione singola in scatola da dieci pezzi).
  • Page 4 L’interrupteur d’allumage est doté d’une isolation double. Par Q640A 1002 quantité d’emballage 100 pcs conséquent aucune mise à la terre n’est requise lorsque Q640A 1010 comme Q640A 1002 sauf TRADELINE (sachet l’interrupteur d’allumage est monté sur un dispositif de unique dans une boîte de dix pièces).

Ce manuel est également adapté pour:

Q640a 1010