Télécharger Imprimer la page

resideo Braukmann KaltecSoft PW50AS Notice D'installation page 11

L'appareil de traitement de l'eau

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10. Settings
10.1 Time
Input: 24-hour mode
4.
Set the time via the
o The clock runs quicker when the
tons are held pressed
Time
10.2 Control valve
All settings at the control valve have to be entered in
the check list!
Incorrect parameter changes can lead to substantial
property damages!
In order to accept changes for the control valve set-
tings, run the programming until the end.
Proceed with the
Capacity setting
10.2.1
1.
Simultaneously press the
conds
If
is displayed, press no further but-
tons (test mode manufacturer)!
Wait for approx. 10 seconds until the current time is
redisplayed!
2.
Enter the calculated set value via the
tons
3.
Press the
button once to go to the next setting
In operation or water consumption the residual capac-
ity is reduced from the set amount to zero.
Residual volume 530 litres
Time-delayed, volume-controlled regeneration
10.2.2
Regeneration is triggered at the set time if the remaining ca-
pacity does not suffice for the next full day
Set to 02:00 a.m. at the factory!
Input: 24-hour mode
Time regeneration
1.
Press the
and
2.
Press the
button once to go to the next setting
MU1H-1412GE23 R1020
and
buttons
and
but-
button!
and
buttons for 5 se-
and
Residual volume 0 litres
buttons to change the time
GB
Forced regeneration
10.2.3
If the programmed number of days between two re-
generations has been reached, a forced regeneration
is triggered at the set time. The forced regeneration is
triggered irrespective of the residual volume.
Set to 7 days at the factory!
Input: OFF up to 99 days
Forced regeneration
1.
Press the
of days
2.
Press the
10.3 Manual Regeneration
There are two manual regeneration possibilities available
1. Possibility
Press the button
Manual regeneration starts immediately
1. Possibility
Briefly press the
Manual regeneration starts at the set time
Operating display flashes
Change to the next regeneration phase
10.3.1
1.
Press the
on phase
but-
If the water conditioning device is in between two phases
(phase display flashes), pressing the button has no ef-
fect
11. Power Failure
11.1 Settings
The time has to be reentered after a power failure
(Chapter 10.1)
All the control valve settings remain and are restored once the
power supply has been reconnected
11.2 General Information
After the power supply has been reconnected, it is recom-
mended to start a manual regeneration (Chapter 10.3)
12. Maintenance
12.1 Block Salt Level
To be checked frequently (e.g. weekly).
1.
Remove the covering cap from the cabinet
2.
Remove the salt lid from the cabinet
3.
Check the level in the cabinet
4.
If the salt level has fallen below 10 cm, Refill block salt
(Chapter 8.2)
5.
Attach the salt lid
6.
Replace the covering cap on the cabinet
11
and
buttons to change the number
button once to accept all the changes
5 seconds
key
button once to go to the next regenerati-
homecomfort.resideo.com