2. Installation
a) Place ozone generator in a dry and well-ventilated area.
b) Ozone generator must be placed on a flat and stable ground.
c) Ozone output of ozone generator has to be connected with ozone inlet of protein skimmer or
ozone reactor by Teflon tube (maximum length: 10 meter).
d) Ozone generator must be protected against back flow water from ozone reactor or protein
skimmer.
3. Operation
Output control)
Current meter
3.1. Preparations before starting the ozone generator
a) Power switch button must be OFF.
b) Ozone output tuning switch is at the minimum value "0%".
c) Gas flow meter is at minimum value "0 l/min".
d) Current meter is "0 ampere".
e) Pressure meter: use screw driver (or cuspate tool) to press the central button on the pressure
meter, turn the pointer needle to "0"(positive pressure). So the ozone generator will work in
the positive pressure.
Notice: For use with negative pressure from the connected unit (like protein skimmer or other
ozone reactor with venturi system), set the value on the pressure meter at "minus 0" mPa. The
pressure meter will now act as a safety device protecting the ozone generator from continuously
producing ozone, while the connected unit is not "sucking in" ozone.
f)
Connect the ozone generator to the correct electricity supply.
10
(Power light)
Power switch on/off
(Working light)
Gas flow meter
(Warning light)