SmartFLeX 8403Multi Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Smartflex
System
Nominal Fitting
Diameter in mm
Welding Voltage in
Volts
The welding time is subject to automatic adjustment according to the external
operating temperature.
Pressing the ENTER
reminds the operator, of all the preliminary operations they must perform to
prepare for the welding to commence.
If the choice is YES, press
next screen that displays
D = Fitting Diameter
T = Welding Time
V = Welding Voltage
After having checked all the entered data for correctness, press ENTER
to commence welding.
If the welding leads are not connected to the fitting, the display shows an error
(error code 31). Press ESCAPE
menu.
Otherwise, if the connections are correct, the welding process commences
and the following screen is displayed:
Fitting Nominal Resistance
in Ohm
Fitting
Measured
Resistance
Ohm
External Temperature
in °C / °F
and, then:
Time remaining in seconds
until the completion of the
welding
Delivered
Power in
Watts
Percentage progress of the
welding
Fitting Symbol
Sma
I (COUPLER)
Diam. =
U welding =
t welding =
Nominal Welding Time
in Seconds
key displays the screen shown on the right, that
, if NO press ESCAPE
to return back to the welding mode main
Nominal Res =
Meas Res =
Temp Ext =
Temp Int =
Internal Temperature
in °C / °F
Welding Voltage
in Volts
T.rem = _____ U = ____
P = _______ E = ______
■■■■□□□□□□□
0
% Welding
100
Fitting Type
to proceed to the
Total Energy
consumed in Joules
10
Scraping/Cleaning ?
Yes ENT
No
ESC
D = _____ T = ______
V = _____ OK = ENT

Publicité

Table des Matières
loading

Table des Matières