ENGLISH
BATTERY REPLACEMENT:
• Unscrew the lens ring nut anticlockwise.
• Remove the battery holder.
• Make sure to insert the batteries observing the correct polarity marks
(+ or -) shown on the holder.
• Insert the battery holder into the body of the torch.
• Lubricate the O-ring seal with a silicone grease film.
• Screw the lens ring nut clockwise.
• Switch on the torch to test.
CHECKS BEFORE DIVING:
• If the torch has not been recently used, check the state of the SHOT
torch batteries and switch on the torch to test.
• Check for the perfect seal of the body.
• When under water, check that there is no continuous discharge of air
bubbles from the torch body.
In case of water leakage into the torch, open it, remove the batteries and
rinse immediately the internal parts in fresh water, then wipe with a
cloth and dry with a warm air source, paying particular care to mechanical
parts. Remove the oxide, if any, deposited on metal parts and test for cor-
rect operation.
If the quantity of water leaked into the torch is considerable and if it has
remained there for a long time, open the torch and rinse immediately the
internal parts in fresh water; in such occurrence immediately contact a
suitable servicing centre or the nearest Seac Diving pro centre.
16
FLOODING:
LIMITS OF USE:
• The maximum operating depth is 100 m.
• Owing to the high temperatures reached by the bulb, the lamp should be
used only under water.
BULB REPLACEMENT:
• Unscrew the lens ring nut.
• Extract the bulb to be replaced and insert the new one as shown by the
two small arrows on the reflector holder.
• Reinsert the whole assembly making sure that the bulb fits in the reflector
hole.
• Lubricate threaded parts and O-rings, then screw the lens ring nut.
MAINTENANCE AND TRANSPORT:
Compliance with the following instructions is required:
• Always carry the torch inside a bag protecting it from any shocks.
• Avoid prolonged exposure to sunrays.
• At the end of each dive (sea, lake or swimming-pool) always rinse in fresh
water and wipe.
• Check the state of O-rings every time the body is opened.
• Clean and lubricate the parts involved in the opening process with silicone
grease.
• It is recommended to have the product inspected every year at an
authorized SEAC SUB centre.
ENGLISH
17