Function
Function description
number
1
DETECTOR – plug-in detector PLD function setting 00 -Detector not
used 01 -Detector has security function only (blocks closing) 02 -Detector
has security + closing function (automatically closes after car passes) set
parameter 05 to value 01
2
RADIO1 – plug-in receiver Rxd2pp relay A function setting 00 -Relay
A opens the barrier or inductive detector PLD is used as opening (after
car enters the loop barrier opens automatically, inductive loop connected
to input ANT) 01 -Relay A „step-by-step" 02 – Not implemented (do not
programme)
3
RADIO2 – plug-in receiver Rxd2pp relay B function setting 00 -Relay
B switched off 01 -Relay B closes barrier
4
LAMP – flash light or boom warning lighting function setting 00 -
Warning lights blink during movement only 01 – Warning lights blink
permanently
5
FOTO – closing impulse memory while FOTO input interrupted 00 –
While FOTO input interrupted control unit ignores close command 01 –
While FOTO input interrupted control unit remembers closing impulse,
when FOTO input connected again command is carryed out
6
TIMER – setting time of automatic barrier closing after opening 00 –
Automatic closing switched off 01 – 99 -Automatic closing activated,
number set corresponds to time in seconds
7
DELAY – delay of closing after close command (flash light pre-
flashing) 00 – Delay switched off 01 – 99 – Set time of delay in seconds
8
Semaphore switch to STOP signalling time setting 00 – Semaphore
switches with close command 01 – Semaphore switches with activation
of some security input (it means when car enters the area close to the
barrier) 02 -Semaphore is controlled externally by powering up (24V DC)
the SEM input
9
Setting of barrier reaction after activation of security FOTO input or
detector while closing 00 – Barrier stops and returns to open position
and continues according to parameter 05 01 – Barrier stops and waits
while the security input is operated, after security input is opened barrier
finishes itʼs move 02 -Barrier stops and waits while the security input is
operated, after security input is opened barrier finishes itʼs move with 2
second delay
10
Motor overload detection – in case overload occurs during motor
run (violent stopping) 00 -Function switched off (motor runs for standard
time) 01 – Function is active, time of motor run is set (01 – 20s)
11
Closing blocked using OPEN input 00 -Function switched off 01 – In
case the contact on OPEN input is operated it is not
(utilisé dans les gardiennages où il est nécessaire que la barrière reste
ouverte pendant qu'un véhicule à remorque passe), puis cela continue
selon le paramètre 05
12
Temps de l'extension de la fermeture automatique 01 - 10 Le ration
avec lequel le temps de fermeture automatique (paramètre 06 – TIMER )
est multiplié
13
Temps de remise à zéro de la fermeture automatique et de la lumière
instantanée 00 – le temps n'est pas remis à zéro 01 – le temps
commence à tourner après l'activation de n'importe quelle entrée
Programmables functions table:
Values range
Preset
00 - 02
1
00 - 02
0
00 - 01
0
00 - 01
0
00 - 01
1
00 - 99
0
00 - 99
0
00 - 02
0
00 - 02
0
00 - 20
0
00 -
01 – 10
01
00 – 01
00