OPERATING INSTRUCTIONS
FOG JET TROLLEY
Prepare the area that is to be fogged, by closing all access points and switch
the ventilation system Off.
Close the area to personnel traffic, Post hazard warning signs at access points,
if needed.
Remove the screw cap from the Fogjet Vessel.
Prepare, in the vessel, up to 25 litres of Sanitiser diluted with clean cold water
to the concentration recommended by the chemical manufacture.
Replace the screw cap on the Vessel to minimise spillage during
manoeuvring. The ventilation aperture in the centre of the cap must not be
obstructed.
Position the Trolley strategically in the area to be fogged, ensuring that no
obstruction to the jet stream will occur within 3 metres.
Plug the air line on the unit into a valved, clean, compressed air service outlet
that incorporates a pressure regulator set to a nominal value of 4 Bar Gauge
pressure.
Turn the compressed air valve to the ON position, observe and confirm that the
Fogjets are all working and retire from the area.
After a period of time determined by calculation,
experience. Turn the air valve to the OFF position and disconnect the
compressed air supply.
Switch the ventilation system ON.
Remove Hazard warning signs.
Remove the Fogjet Trolley to the stores.
*
To calculate the time needed to fog a given space go to
http://www.central-hygiene.co.uk Click - 'Help and Advice' then 'Fogjet
Calculator'. Then follow the instructions.