OWNERS MANUAL
HOSE &REGULATOR ASSEMBLY AND REPLACEMENT
1. This fireplace comes equipped with a standard gas hose and regulator including the appliance side
connection for Cylinder Connection Device. The gas hose and regulator supplied with thisfire table
must be used. In case it is not included, follow the description specifying which type to use.
Type of regulator: Low pressure LPG regulator;
Regulator for specified standards:EN 1612-:2013 Only a hose and regulator specified by manufactu-
rer can be used for replacement.
a. The connection incorporates a magnetic flow limiting device that acts
leak is detected between the regulator
and the burner valve.
b. If the burner valve is open prior to the gas cylinder service valve being opened, the connection will
interpret this free flow of gas to be a leak.
c. The connection safety feature will reduce gas flow from the regulator to the appliance to a
minimal level.
d. Be sure that the burner control valve is closed prior to opening the gas cylinder service valve to
ensure that the connection flow limiting
device is not triggered mistakenly.
e. If the connection flow limiting device is triggered mistakenly, close the gas cylinder service valve
and the burner valve, wait 10 seconds to
allow the device to reset, open the cylinder service valve, then open the burner valve and light the
fireplace as per lighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts
any hot surface.
3. Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the fire table. If the hose shows signs of cracks, abrasions, cuts
or damage of any kind, do not operate the appliance. Fix or replace the hose as required
before using the appliance. For assistance with repair or replacement of the hose. Use only
replacement parts from the manufacturer.
b. Inspect the seal inside the service valve on the gas cylinder when replacing the cylinder or at least
once per year. If there is any indication of damage, have the seal replaced by a certified gas dealer
before operating the appliance.
4. Do not use tools to tighten the connection nut onto the gas cylinder service valve.
Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the connection on to the
gas cylinder service valve.
6. "Leak Test" should always be performed after attaching the connection to the gas cylinder
service valve.
7. For the connection of the hose and regulator to the tank, refer to the "Connection" section of the
gas cylinder section.
GAS HOSE CONNECTIONS
Two adults will be needed, to assist each other with assembly. Upraise the fire pit and attach the hose
to the manifold inlet nipple and tighten hose clip, or secure the hose to the manifold inlet fitting as
shown in FIG.01 & FIG.02 below.
NOTE: Installation and service must be performed by a qualified installer, service agency or your gas
provider and Plastics hose tubing and assemblies.
length of tubing or flexible hose usable for the gas supply to the appliance from the gas cylinder:50cm
to limit the flow of gas if a