Télécharger Imprimer la page

Dacor RNMD30B Directives D'installation page 5

Four micro-onde tiroir
Masquer les pouces Voir aussi pour RNMD30B:

Publicité

Les langues disponibles

Les langues disponibles

24" Flush Mount Installation Instructions
Suggested electrical
outlet location
Figure 2B
1
A. 22
/
" (561.97 mm) mounting
8
cleat opening width
3
B. 24
/
" (614.35 mm) minimum
16
1
24
/
" (622.3 mm) maximum
2
flush opening width
3
C.
/
" (19.05 mm) shelf
4
Move oven location
downward for extended
countertops for better
viewing angle.
7
16
/
"
8
(428.62 mm)
flush opening
height
Front face of cabinet
Figure 2C
2. Install deflector as shown in Figure 3A.
Shelf detail showing the deflector vent during installation.
Position deflector vent and mark holes. Pre drill using a
Figure 3A
Shelf detail showing the deflector vent installed.
Figure 3B
Heading
No oven
A
Anti-Tip block
B
C
Front view
Anti-Tip
block
3
/
"
(19.05 mm)
4
shelf
3
1
/
" (44.45 mm)
4
front face of shelf
Side view
1
/
" (1.57 mm) bit before mounting.
16
3. Place the drawer adjacent to the wall or cabinet
opening. Plug the power supply cord into the electrical
outlet.
4. Carefully guide the drawer into the prepared opening.
Avoid contact with the sides of the cutout opening and
also pinching the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting
flanges touch the cleats mounted in the cabinet
opening.
6. Open the drawer. Using the 4 holes on the drawer as a
template, pre drill the cabinet using a 1/16" (1.57 mm)
bit. See Figure 4.
Figure 4
7. Secure the drawer with the 4 screws supplied.
E5
Mounting
flange

Publicité

loading

Ce manuel est également adapté pour:

Rnmd30sRnmd24bRnmd24sDmr24m977ws