4
Conversion Instructions
Installation should be done by a qualified service person.
9
Paste Natural gas convertion label
·ATTENTION: This unit has been converted for use with Natural Gas.
Convert model# GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Convert gas type: Natural Gas
Manifold pressure: 7"
Input rate after conversion:
GBC1707WT-C (30,000 BTU);
GBC1856W-C (48,000 BTU main burner + 12,000 BTU side burner);
GBC1768WC-C (60,000 BTU main burner + 12,000 BTU side burner);
GBC1870W-C (40,000 BTU main burner + 12,000 BTU main twin burner + 12,000 BTU side burner).
This appliance was converted on _______(day-month-year) to Natural gas with Kit No. _______by __________________
(name and address of organization making this conversion), which accepts the responsibility that this conversion has been properly made.
· ATTENTION: Ce barbecue a été modifié afin de pouvoir être utilisé avec du gaz naturel.
Convertissez le modèle # GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Type de gaz de conversion: Gaz Naturel
Pression du manifold: 7"
Taux d'entrée après conversion:
GBC1707WT-C (30 000 BTU);
GBC1856W-C (Brûleur principal de 48 000 BTU + brûleur latéral de 12 000 BTU);
GBC1768WC-C (Brûleur principal de 60,000 BTU + brûleur latéral de 12,000 BTU);
GBC1870W-C (Brûleur principal de 40 000 BTU + double brûleur principal de 12 000 BTU + brûleur latéral de 12 000 BTU).
Cet appareil a été converti sur _____________ (jour-mois-année) au gaz naturel avec le kit no. _______by __________________
(nom et adresse de l'Organisation effectuant cette conversion), qui accepte la responsabilité que cette conversion a été faite correctement.
VFK1702W-C-EF-NG Convsesion Label-F100
10
Perform a Leak Check and Follow Up Lighting Instruction
Perform a leak check:
1, Do NOT operate if gas leak is present. Gas leaks may cause a fire or explosion.
2, You must follow all leak-checking procedures before operating. To prevent fire or explosion hazard when testing for a leak:
a. Always perform leak test before lighting the grill and each time the natural gas line is connected.
b. No smoking. Do NOT use or permit sources of ignition in the area while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do NOT use matches, lighters or a flame to check for leaks.
e. Do NOT use grills until any and all leaks are corrected.
If you are unable to stop a leak, turn natural gas main valve to "OFF." Disconnect natural gas line. Call a gas appliance serviceman.
Lighting Instruction:
W CAUTION: Keep outdoor gas cooking appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause an explosion.
1.
Open lid.
2.
Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube can lead to a fire.
3.
All control knobs must be in the " OFF" position.
4.
LP: Connect LP gas tank per "Installing LP Gas Tank" section. / NG: Connect NG main line per "Installing Natural Gas Line" section.
5.
LP: Turn LP gas tank valve to "OPEN." / NG: Turn natural gas main valve to "ON."
6.
Push and turn any control knob to (HIGH). The burner should light. If it does not, repeat up to three times.
7.
If ignition does not occur in 5 seconds, turn burner control knob " OFF," wait 5 minutes, and repeat lighting procedure.
8.
If igniter does not light burner, use a lit match secured with the Lighting Rod (included with grill) to light burners. Access the burners through the cooking grid and heat plates. Position lit match
near side of burner.
Important: Always use the Lighting Rod (included) when lighting burners with a match.
9.
After lighting, observe the burner flame. Make sure all burner ports are lit and flame height matches illustration in above model's instruction manual .
Note: Each burner lights independently - repeat steps 5-9 for the other burners.
WARNING:
This conversion kit shall be installed
by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes
and requirements of the Authority Having Jurisdiction.
If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon
monoxide may result causing property damage,
personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
specified in the manufacturer's instructions supplied
with the kit.
Convet model# GBC1707WT-C, GBC1856W-C,
GBC1768WC-C, GBC1870W-C.
Convet gas type: Natural Gas
Manifold pressure: 7"
Input rate after conversion: GBC1707WT-C (30,000 BTU
main burner), GBC1856W-C (48,000 BTU main burner
+ 12,000 BTU side burner), GBC1768WC-C (60,000 BTU
main burner + 12,000 BTU side burner), GBC1870W-C
(40,000 BTU main burner + 12,000 BTU main twin
burner + 12,000 BTU side burner).