ENGLISH
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during
servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened
and may not be corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally
free from any deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be
replaced.
The mains cables must be in impeccable condition and should be replaced immediately
when even a small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation
openings should be cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surroundings can cause
greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified
personnel!
SPECIFICATIONS
Mains Input:
Total Power consumption:
Sound Control:
Laser Power:
µ-STAR & µ-QUASAR LASER:
µ-QUANTUM LASER:
µ-PHOTON LASER:
Laser radiation class:
Beam diameter @ aperture:
Divergence (each beam)
Divergence (total output)
Working temperature:
Laser Safety Standard:
Size:
Weight:
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website:
JB SYSTEMS
®
DC 12V / 600mA
5,7W
Internal microphone
40mW Green CW laser (λ = 532nm)
100mW Red CW laser (λ = 650nm)
80mW Blue CW laser (λ = 450nm)
100mW Red CW laser (λ = 650nm)
40mW Green CW laser (λ = 532nm)
80mW Blue CW laser (λ = 450nm)
3R
<5mm
<2 mrad
<160°
10°C to 40°C
EN/IEC 60825-1 Ed2, 2007-03
117 x 92 x 46 mm
0.35kg
www.beglec.com
7/36
USER MANUAL
µ-LASER