Télécharger Imprimer la page

Sunex Tools SX10A Instructions D'utilisation page 3

Publicité

Les langues disponibles

Les langues disponibles

AIR SUPPLy
Air
Length of Pipe (ft.)
Flow
CFM
50
10
1/2"
20
3/4"
30
3/4"
40
1"
50
1"
70
1"
Never mount oil and water extractor on or near the air compres­s­or.
During compression, air temperature is greatly increased. As the air cools down to room temperature, moisture condenses in the air line, on
its way to the spray gun. Therefore, always mount the oil and water extractor at a point in the air supply system where the compressed air
temperature is lowest.
Drain air lines­ properly.
Pitch all air lines back­ towards the compressor so that condensed moisture will flow back­ into the air receiver where it can be drained off.
Each low point in an air line acts as a water trap. Such points should be fitted with an easily accessible drain. See diagram above.
TyPES OF INSTALLATION
This spray gun is rugged in construction, and is built to yield exceptional value. The life of this product and the efficiency of its
operation depend upon a k­nowledge of its construction, use and maintenance.
Air Inlet
Atomization
Fluid
Pressure
Control
Gauge
Screw
Oil and Water
Extractor
Fluid Siphon Cup
Air Hose
SIPHON FEED CUP HOOKUP
Air pressure for atomization is regulated at
extractor. Amount of fluid is adjusted by fluid
control screw on gun, viscosity of paint, and
air pressure.
Air Inlet
Fluid
Control
Screw
Fluid
PRESSURE FEED TANK HOOKUP
(Single Regulator)
Air pressure for atomization is regulated
at extractor, fluid pressure at tank­ regulator.
SX10A: Parts Breakdown & Operating Manual
100
150
200
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
Fluid Control
Screw
Fluid Siphon Cup
PRESSURE FEED CUP HOOKUP
For fine finishing with limited spraying. Air pressure
for atomization is regulated at extractor; fluid
pressure at cup regulator. For heavy fluids and
internal mix nozzle spraying, fluid adjusted by
control screw on gun.
Air
Extractor
Pressure
Tank­
Pitch pipe back
toward air receiver
Compressor Unit
Drain
Air Inlet
Atomization
Pressure
Gauge
Oil and Water
Extractor
Air Hose
Fluid
Control
Screw
Main
Line
Fluid
Outlet
PRESSURE FEED CIRCULATING HOOKUP
For fine finishing with limited spraying. Air pressure for atomization is regulated
at extractor; fluid pressure at cup regulator. For heavy fluids and internal mix
nozzle spraying, fluid adjusted by control screw on gun.

Install drain at
each low point
25 Feet
or More
Oil and Water Extractor should be at least 25 ft.
from the compressor, farther if possible.
Fluid
Control
Screw
Fluid
PRESSURE FEED TANK HOOKUP
(Double regulator)
Air pressure for atomization and fluid supply is
regulated by two individual air regulators on tank­.
Air Inlet
Extractor
Air
Oil & Water
Extractor
Drain
Air
Air Inlet
Supply
Pressure
Tank­
Fluid
Regulator
Fluid
rev. 04/29/06

Publicité

loading