ENGLISH
INSTALLATION GUIDELINES
This unit may only be installed and electrically connected by an
Electrical installation should strictly follow all safety rules and
The complete installation should be approved by an authorized
expert before it will be taken into operation! Each change to an
Before connecting ANY equipment you should ALWAYS check the
voltage on the 3 phases: not following this rule can cost you a lot
MAINS INPUT: the unit should be connected to the mains via a 5pole 380-400V 63A CEE socket. The
maximum overall power is 44.160Watt which may never be exceeded!
OUTPUTS: each phase is connected via
is 14.490Watt, each 16A output socket supports maximum 3.680Watt which may never be exceeded!
MAINTENANCE
Switch the unit off and unplug the mains cable BEFORE servicing!
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
The unit and its installation conditions should be inspected and approved every 3 months by an authorized
expert!
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
BRITEQ
®
DANGER TO LIFE / EQUIPMENT:
authorized and qualified electrician!
technical norms for electrical installations in your country!
existing installation should be re-approved as well!
of money due to broken equipment. Briteq CANNOT be held
responsible in such cases!
4
DANGER TO LIFE:
separate 16A output sockets. The maximum power per phase
5/30
USER MANUAL
PD-63SH