6. Check for satisfactory operation throughout the speed range.
7. Open the FWD/REV connection to COM to verify motor brakes to zero speed.
8. If operation is satisfactory, no readjustments are needed.
9. If instability or surging is observed, or if maximum and minimum speed settings need further
adjustments then see "TRIMPOT ADJUSTMENT CHART & PROCEDURE".
10. For other problems, consult page 10, "IN CASE OF DIFFICULTY".
TRIMPOT ADJUSTMENT CHART & PROCEDURE
Settings apply when using a 5K ohm master speedpot. This chart is used
in conjunction with the adjustment procedure and is approximate.
130LC12
130HC12
120 VAC input;
0-90 VDC output
130LC100
130HC100
120 VAC input;
0-90 VDC output
Operation of the control beyond ±10% of the normal line voltage could result
in re-adjustment. These adjustments are permanent; periodic re-adjustment
is normally not needed.
C.L.
I.R.
MAX
MIN
HP
1/50
1/20
1/8
1/8
1/4
1/3
1/2
3/4*
1.0*
Settings apply when using a 5K ohm master speedpot. This chart is used
in conjunction with the adjustment procedure and is approximate.
HP
C.L.
I.R.
MAX
1/20
1/8
1/4
1/4
1/3
1/2
3/4*
1.0*
1.5*
2.0*
7
MIN
132LC25
132HC25
240 VAC input;
0-180 VDC output
132LC200
132HC200
240 VAC input;
0-180 VDC output