- Mode D: Sequence with simultaneous activation
of legs and arms.
Arms
9
8
Waist
7
6
Legs
5
4
3
2
Boots
1
0
● Thermotherapy Function
1
1
Time display and adjustment
2
Temperature control
3
By pressing until "- -" appears, the
corresponding area will not heat
4
Start or Pause the operation of the machine
- The preset values when switching on the device
are as follows:
• Length of treatment: 30 minutes
• Temperature: 35ºC
• Heating of all activated sections
- Set the previous parameters
• Length of treatment: maximum 60 minutes
• Temperature adjustment: from 35ºC to 65ºC at
intervals of 3ºC
• You can turn off the heating of one or several
sections of the suit.
EN
6
2
3
● Electrostimulation Function
1
1
Time display and adjustment
2
Mode display and adjustment
3
Adjustment of pulse intensity for each section
4
By pressing until "- -" appears, the
corresponding part will not activate
5
Start or Pause the operation of the machine
- The preset values when switching on the device
are as follows:
• Length of treatment: 30 minutes
• Operating mode: A
• Pulse intensity level: 01
4
• Operation of all activated zones
- Set the previous parameters
• Length of treatment: maximum 60 minutes
• 4 pre-set work modes: A, B, C, D
• Adjustment of pulse intensity for each section:
from 1 to 15
• You can deactivate the operation of one or
several of the zones
- Definition of preset modes:
• Mode A: Long pulses
• Mode B: Medium pulses
• Mode C: Short pulses
• Mode D: Continuous
CLEANING AND MAINTENANCE
● Before cleaning the device, unplug it from the
mains.
● Clean the device with a soft, dry cloth. Do not use
liquids to clean it.
● After each use, the various components and
accessories must be sterilised and left to dry.
● For maintenance or repairs of any part of the
product, please contact your distributor or
specialised technician.
3
4
2
5