INTRODUCTION
EN
This instruction sheet provides you with the information required to safely
own and operate your Little Giant product. Retain these instructions for
future reference.
The Little Giant product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you long and
reliable service. Little Giant products are carefully tested, inspected, and
packaged to ensure safe delivery and operation. Please examine your unit
carefully to ensure that no damage occurred during shipment. If damage
has occurred, please contact the place of purchase. They will assist you in
replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PRODUCT.
KNOW THE PRODUCT'S APPLICATION, LIMITATIONS, AND POTENTIAL
HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING
ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE!
DESCRIPTION
HOW FILTRATION WORKS: Biological and mechanical filtration are essential
to every pond; without them debris and ammonia from accumulated fish
waste would harm your fish.
Biological filtration uses bacteria on filter media to nitrifiy the ammonia in
a pond, where mechanical filtration removes only debris. Both of these
filtration techniques combined are called bio-mechanical filtration, and
provide a cleaner pond and healthier environment for your aquatic life.
HOW BIO-MECHANICAL FILTRATION EXCELS: Bio-mechanical filtration
uses a colony of bacteria on the surface of the filter media to convert
dissolved nitrogenous waste to harmless compounds. When the bacteria
are given the proper environment, they grow in a thin biofilm on the surface
of each piece of media. The larger the surface area, the larger the bacterial
colony.
SAFETY GUIDELINES
Read all instructions thoroughly. Failure to follow the instructions could
result in serious bodily injury and/or property damage.
INSTALLATION
CAUTION: 2" valves are supplied with PTFE tape already applied to the
unions. It may be necessary, however, to apply more PTFE tape if the valve
leaks upon installation. DO NOT use any sealant other than PTFE tape, as
this can cause the valve to crack or leak, either immediately or over time.
DO NOT over-tighten the unions. HAND TIGHTEN ONLY. DO NOT use any
tools. Use care during installation; problems resulting from over-tightened
unions and/or the use of any sealant or putty will not be covered under
warranty.
CAUTION: For the pressurized bead filter to perform bio-mechanical
filtration, the media must first establish itself enough to process the dissolved
ammonia. Depending on temperature, climate, weather conditions, fish
load, and feed rates, this can take 2 - 4 weeks. Until the bacteria colony
has grown large enough, the pond owner MUST monitor the ammonia and
nitrates in the water and correct dangerously high levels.
CAUTION: In a pond with heavy algae content, change the water before
installing the filter.
NOTE: For ease of maintenance, install a ball valve between the pump and
the filter, and a check valve between the filter and the pond.
ITEM
ARTICLE
ARTÍCULO
PBF2000
PBF4000
PBF6000
*CAUTION: Do not exceed maximum pressure. • *MISE EN GARDE : Ne pas dépasser la pression maximale. • *CUIDADO: no exceda la presión máxima.
PRESSURIZED
BEAD FILTER
SIZE (Diameter x Height)
TAILLE (Diamètre x Hauteur)
TAMAÑO (Diámetro x Altura)
16" x 32"
19" x 36"
24" x 43"
SpecificationS • caRactÉRiStiQUeS • eSpecificacioneS
1. Attach the unions to the valve (Figure 1).
Pump In
Côté alimentation de la pompe
Entrada a la bomba
Pump Out
Côté évacuation
de la pompe
Salida de la
bomba
2. Glue the pipe from the pressure side of the pump to the slip-fitted side of
the union leading to the valve port marked PUMP (Figure 2).
3. Glue the pond return line to the slip-fitted side of the union leading to the
valve port marked RETURN (Figure 3).
4. Glue the waste line from the filter to the slip-fitted side of the union leading
to the valve port marked WASTE (Figure 4). NOTE: Do not reduce the size
of the waste line.
MAXIMUM PSI*
MAXIMALE PSI *
MÁXIMA PSI*
38
38
38
Table 1
Waste Out
Sortie de l'évacuation
Salida de desechos
Figure 1
Figure 2
Figure 3
Figure 4
POND SIZE (Gallons)
TAILLE DU PLAN D'EAU (Gallons)
MaÑo DeL eStanQUe (Galones)
2000
4000
6000
1

Publicité

loading

Sommaire des Matières pour Little Giant PBF2000

  • Page 1 Little Giant product. Retain these instructions for Pump Out Côté évacuation future reference. de la pompe The Little Giant product you have purchased is of the highest quality Salida de la bomba workmanship and material, and has been engineered to give you long and Figure 1 reliable service.
  • Page 2 Figure 6 Figure 9 3. Prime and start the pump according to the pump instructions. Little Giant 3. Loosen both clamp screws and remove the clamp (Figure 10). pumps are recommended with all Pressurized Bead filters (or check with your dealer for an alternative, high-flow pump.)
  • Page 3 5. Use a submersible pump or wet/dry vacuum (with a strainer on the nozzle) RETURNING FILTER TO SERVICE to remove the water from the filter (Figure 12). DO NOT remove the filter 1. Replace the drain cap. media. 2. Lift the filter valve from the body. It may be necessary to loosen the valve by moving it back and forth.
  • Page 4 1. Prendre note de la lecture initiale du manomètre lorsque le filtre est propre. Cette lecture varie d’un plan d’eau à l’autre selon la capacité de la pompe Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec et le type de réseau hydraulique.
  • Page 5 El producto Little Giant que ha adquirido se fabrica utilizando mano de obra y 2. Presione la manija de la válvula de control y gírela a la posición de filtro. materiales de la más alta calidad y ha sido diseñado para prestarle un servicio 3.
  • Page 6 MANTENIMIENTO 5. Apague la bomba. Protección contra temperaturas muy bajas (filtro instalado sobre la 6. Presione la manija de la válvula y gire el puntero a la posición RINSE superficie del terreno) (enjuague). 1. Apague la bomba y cierre las válvulas de la tubería de la bomba y la tubería 7.
  • Page 7 At its discretion, the Company may inspect products either at its facilities or in the field, I. Période de Garantie Applicable and after determination of a warranty claim, will, at its option, repair or replace defective Les produits accompagnés par cette garantie doivent être couverts par cette Garantie parts.
  • Page 8 Pour l’aide technique, entrez s’il vous plaît en contact ..1.888.956.0000 Para la ayuda técnica, por favor póngase en contacto ..1.888.956.0000 www.lg-outdoor.com customerservice@lgpc.com Form 998638 - 04/2012 Rev. 001 ©2012 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Ce manuel est également adapté pour:

Pbf4000Pbf6000