MRGSM/MRSGSM Receiver
4. PROGRAMMING AND DELETING CODES REMOTELY
Remote programming is carried out using the WinAccess software from a computer connected to the Internet.
Find the IMEI number shown on the label attached to the MRGSM card.
Install the WinAccess software and add a GSM-managed site. Add an MRGSM receiver and use the IMEI number to identify it.
Next add the remote controls in the "user" branch by validating the desired channels on the MRGSM relays.
After the site has been synchronized, the remote controls will be operational.
5. PROGRAMMING AND COMPLETE DELETION OF THE CODES LOCALLY
If this feature has been validated in WinAccess, the manual programming button (PROG) can be used to program or delete the radio codes
present in the receiver's memory.
Programming the transmitters locally:
•
Connect the receiver to the power supply (programming can only begin if at least one yellow GPRS reception status LED is on or
flashing.)
•
Press the "PROG" button. Receiver status LED 1 (Red) lights up. This LED indicates the relay that is intended to be associated
with the transmission. To select relay 2 press the "PROG" button a second time (receiver status LED 2 (Green) lights up).
•
Carry out a transmission by pressing the desired button. A different transmission corresponds to each button (channel).
•
During memorisation, the LED will flash slowly. Once the operation is complete, the light stops flashing.
•
If an LED starts flashing quickly, this means the code has already been memorised and is associated with the LED which is
flashing.
•
If all the receiver status LEDS are flashing at the same time, this means the memory is full. The code will not be memorised.
•
Repeat the operation for all the buttons (channels) that need to be memorised, selecting each time the relay to be associated with
the channel.
•
To exit programming, press the "PROG" button again: the receiver status LEDs turn off. Exit is automatic 20 seconds after the last
operation.
•
The codes remain in the memory even if the power supply is cut off.
•
The codes created locally will be automatically transferred to the WinAccess software the next time it is connected.
Programming remote controls locally via GSM:
•
Connect the receiver to the power supply and wait until at least one yellow GSM/GPRS reception status LED is on and not
flashing.
•
Press the "PROG" button. Receiver status LED 1 (Red) lights up. This LED indicates the relay that is intended to be associated
with the transmission. To select relay 2 press the "PROG" button a second time (receiver status LED 2 (Green) lights up).
•
Make a GSM call using the telephone number for the MRGSM receiver (indicated on the label attached to the MRGSM card).
•
The GSM making the call will not be charged for the call.
•
During memorisation, the LED will flash slowly. Once the operation is complete, the light stops flashing.
•
If an LED starts flashing quickly, this means the code has already been memorised and is associated with the LED which is
flashing.
•
If all the receiver status LEDS are flashing at the same time, this means the memory is full. The GSM number will not be
memorised.
•
To exit programming, press the "PROG" button again: the receiver status LEDs turn off. Exit is automatic 20 seconds after the last
operation.
•
The GSM numbers remain in the memory even if the power supply is cut off.
Complete deletion of the codes:
•
Warning, the entire code and GSM number memory will be deleted.
•
Connect the receiver to the power supply (programming can only begin if at least one yellow GPRS reception status LED is on or
flashing.).
•
Hold the "PROG" button down until the receiver status LEDs (red and green) start to flash.
•
Release the button and press again to confirm the deletion. The LEDs will be on and not flashing during the operation, they will
start to flash more rapidly once the operation is complete.
6. TECHNICAL CHARACTERISTICS
Power supply
Average consumption in operation/at rest 200 mA / 60 mA (Provide a 1A power supply)
Number of codes that can be memorised
Number of channels
Types of output
Output
Capacity of the contacts
Inputs with configurable functions mode
Extension
Frequencies
Operating temperature
Storage temperature
Dimensions and weight
Protection index
DÉCLARATION OF COMPLIANCE
Prastel declares that the following devices: MRGSM AND MRSGSM RECEIVER ARE COMPLIANT with the compulsory criteria of directive
99/05/EC (R&TTE). The full declaration of compliance is available from Prastel
ENGLISH
12-24
AC/
(50/60Hz)
1000
2
monostable, bistable and timed
NO/NC relays
0,5 A @ 24 VAC/DC
2 (Opening controls, vehicle detection, timed or
untimed alarms, wiegand, etc.)
Up to 6 RS485 radio receivers
433 Mhz (MRGSM), 868 MHz (MRSGSM)
-20/+55 °C
-40/+85 °C
145 x 108 x 45 mm – 220 g.
IP 54
ISMRGSM_09_15.doc