1 TECHNICAL CHARACTERISTICS
Dimensions outside:
width
depth
height
Net weight, approx.
Gross weight, approx.
Adjustable thermostats
Inside available volume: 10+10+10 liters ( 3 boxes
130x280x400 mm max.)
Hermetic compressor
Overload protector
Noise level lower than 70 dB (A)
IMPORTANT
Read electrical ratings written on the data
plate under the individual units. Data
p l a t e s p e c i f i c a t i o n s w i l l a l w a y s
s u p e r s e d e t h e i n f o r m a t i o n i n t h i s
manual.
Specifications are subject to change
without notice.
2 INTRODUCTION
Please read all sections of this manual
thoroughly to familiarize yourself with all
aspects of the unit.
Like all mechanical products, this machine
will require cleaning and maintenance.
B e s i d e s , d i s p e n s e r w o r k i n g c a n b e
compromised by operator's mistakes
during disassembly and cleaning. It is
strongly recommended that personnel
responsible for the equipment's daily
operations, disassembly, and assembly, go
through these procedures in order to be
properly trained and to make sure that no
misunderstandings exist.
3 INSTALLATION
1 - Remove the corrugate container and
packing materials and keep them for
possible future use.
2 - Inspect the uncrated unit for any possible
damage. If damage is found, call the
delivering carrier immediately to file a
claim.
3 - Install the unit on a counter top that will
support the combined weight of dispenser
and product.
4 - A minimum of 15 cm (6") of free air space
Delta
210
310
5 - Before plugging the unit in, check if the
cm
36
50
cm
55
55
cm
72
72
kg
31
35
kg
36
39
n
1
1
4 TO OPERATE SAFELY
1 - Do not operate the dispenser without
2 - Do not operate the dispenser unless it is
3 - Do not use extension cords to connect the
4 - Do not operate the dispenser unless all
5 - Do not put objects or fingers in panels
6 - Do not remove panels for cleaning or
OPERA 210/310 UL
behind the unit should be allowed to
guarantee adequate ventilation.
voltage is the same as that indicated on
t h e d a t a p l a t e . P l u g t h e u n i t i n t o a
grounded, protected single phase electrical
s u p p l y a c c o r d i n g t o t h e a p p l i c a b l e
electrical codes and the specifications of
your machine. Install the unit so as the
plug can be easily accessible. When the
unit has no plug, install a proper grounded
plug, in compliance with electrical codes in
force in your area, suitable to at least
10 Amp 250 Volt (220-230 Volts 50-60 Hz
a r e a s ) a n d 2 0 A m p 2 5 0 V o l t ( 1 0 0 -
115 Volts 50-60 Hz areas) applications.
Should you prefer to connect the unit
directly to the mains, connect the supply
cord to a 2-pole wall breaker, whose
contact opening is at least 3 mm. Do not
use extension cords.
ATTENTION
Failure to
provide proper
ground according to applicable electrical
codes could result in serious shock
hazard.
ATTENTION
Do not install the dispenser outdoor or
open to the rain.
reading this operator's manual.
properly grounded.
dispenser.
panels are restrained with screws.
louvers.
routine maintenance unless the dispenser
is disconnected from its power source.
electrical
7