4.1 Supply Voltage Input Connection of the Device
Power Supply Connection
a
L
N
4
5
EXTERNAL
FUSE
(1A T)
Supply
Switch
Supply Voltage
V
230V
( %15) 50/60Hz ,
±
V
115V
( %15) 50/60Hz,
±
V
24V
( %15) 50/60Hz ,
±
Z
10...30 V
1.5 W
Must be determined in order.
Note-1 : External fuse is recommended.
4.2 Device Label and Connection Diagram
V
230V
CONNECTION DIAGRAM
16A @
V
V
250V
1HP
230 V
± 15%
50/60Hz - 1.5VA
OUTPUT
NO
C
NC
LINE
LOAD
c
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
c
important in electrical connection.
External fuse that on
phase connection.
External fuse that on
connection.
8
7
LOAD
N
16A T Fuse
L
V
power supply inputs must be on
Z
power supply inputs must be on (+)
16A
V
@250V
1HP
OUTPUT
a
NO
C
NC
1
2
3
4
5
L N
6
7
8
6

Publicité