Télécharger Imprimer la page

Denios IBC Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

Betriebsanleitung
English
1. General Instructions
The general instructions for storage systems, material no. 103041, in the current version, must be observed.
National standards and safety regulations must be observed.
2. Special safety instructions
The storage of flammable liquids included in the European VbF hazardous materials classifications AI,
AII and B (also R10, R11 and R12 classifications included in regulations governing hazardous materi-
als) is prohibited.
If you are storing liquids included in the groups below, evidence of the density and media resistance of the sump
materials is not required:
Watery solutions from organic acids up to 10%, mineral acids up to 20% such as acidic hydrolysing salts in
watery solutions (pH<6), apart from hydrofluoric acid, oxidising acids and their salts.
Inorganic alkalis such as alkaline hydrolysing salts in watery solutions (pH>8) apart from ammonia solu-
tions and oxidising solutions from salts (for example hypochlorite).
Inorganic solutions, non-oxidising salts with pH values between 6 and 8.
3. Use and intended purpose
The stations are use for the safe storage of KTC's (cubic tank containers) and IBC's.
Only store substances to which the material of the sump is resistant.
See the General Operating Instructions.
4. Technical detail
Design
-
Manufactured from acid and alkali resistant polyethylene.
-
No steel components have been used to ensure total corrosion protection.
Fitted with fork lift truck pockets for ease of transportation with a fork lift- or pallet truck.
-
The storage platform acts as a safety measure to prevent the IBCs from slipping.
-
5. Assembly
Place the sump / storage system on level ground and place the grid on the sump.
Denios accessories facilitate the loading, storage and dispensing from the sump / storage system.
6. Specifications
See type label.
7. Operation
Place the containers on the IBC station with suitable equipment.
IBC stations may only be transported on fork lift trucks or high lift stackers with a sufficient load carrying ca-
pacity.
Check IBC / KTC are positioned safely and secure to prevent falling over or down!
Safe filling is possible over the collecting sump.
Access to the IBC station by unauthorised persons is prohibited!
The IBC station must under no circumstances be exposed to direct sunlight or higher temperatures
over a lengthy period, as otherwise due to the material a reduction in inherent stability and shape
stability may occur!
Do not transport filled!
8. Maintenance and Servicing
The inspection and maintenance of the storage system/sump must be carried out in accordance with
the directions in the general operating instructions enclosed in the annex.When replacing parts only
the manufacturer's original parts may be used!
IBC-Station
Seite 4 von 8 Seiten