HIGH VOLTAGE ELECTRICAL CONNECTIONS
Capacitor and Single-phase Motor:
M
16
15
14
24
23
OPERATING MODES
Automatic / Semiautomatic:
Automatic Operation: any pulse opens the gate,
the gate stays open as long as the Dwell time expires
as set by T2 trimmer, then it closes automatically, no
pulsing is required.
Semi-automatic Operation: any pulse opens the
gate that stays open. A second pulse to Close is
required for the gate to close.
Time clock:
How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any
further pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On
expiring and after the pre-set dwell time the gate is closed automatically.
T4 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
ON= Automatic Closing
-
+
OFF= No Automatic. Semi-automatic
Pedestrian Trimmer T4
3
set on to zero
Drwg. No. 4136
Flashing lamp:
T1
T2
-
-
+
+
DWELL TIME from
MOTOR RUN TIME
2 up to 255s
OPEN/CLOSE
from 2 up to 255s
DIP-SWITCH N°3
ON= Automatic Closing
OFF= No Automatic. Semi-
3
automatic closing by pulse
closing by pulse
DIP-SWITCH 4 and 7:
ON: Pre-flashing
OFF: No pre-flashing
4
ON: Lamp is not operating during
Dwell time. Automatic mode.
OFF: It flashes during Dwell Time.
18
17
7
Automatic Mode.
Hold on switched (Deadman) control:
Open and Close operations are achieved "by holding a switch on" (no
relay self-holding in involved) therefore a phisical attendance is required to
keep the gate opening or closing until either the button or key is released.
DIP-SWITCH N°6=ON
6
3
4
Power supply:
20
19
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
Pedestrian Opening:
from 3 to 30s. It can be activated
by any pulse (eg. by remote
NO
-
+
Trimmer T3
22 21
from 2s up to 255s
Trimmer T4
-
+
control) superior to 2s
3
4
the gate opener
Made in Italy