Troubleshooting
PROBLEM
Motor does not start
Water does not circulate
Liquid spewing from unit
Technical Data
SC-DS-05
Pump Type
Motor
Maximum Flow
Maximum Head
Motor Rating
Temperature Range
Dimensions
Capacity
Hose Threaded Connections
© 2018 All Rights Reserved.
PROBABLE CAUSE
• Switch not on
• No power
• Bad connection
• Internal pump pressure
switch senses high pressure
• Failed switch
• Failed motor/pump
• Blown fuse
• Pump not working
• Liquid level too low
• Too much descaling solution
Diphragm
1/6 HP, 115v. 1 Amps 50/60 Hz
(1/6 HP, 220 V, 0.6 Amps, 50/60 Hz)
3 GPM [11 Lpm]
69 Feet
Intermittent
0° F to 130° F+ (54°C)
Height 19", Diameter 14", Weight: 11 lbs
[with bucket]
4 gal [15 L]
Female Garden Hose
SOLUTION
• Turn switch on
• Check for power at outlet
• Check for loose wire connections
• Ensure output of pump is
not blocked
• Replace
• Replace
• Replace
• Replace pump head or clean
and repair
• Make sure liquid level is above
inlet hose strainer in bucket
while circulating
• Stop adding acid.
• Remove some liquid, neutralize
and discard according local
regulations
7