TROUBLESHOOTING:
The Ready/Status light signals various errors or problems. A cycle of red flashes indicates an error.
The number of flashes in a cycle corresponds to the symptom in the table below:
Status/Diagnostic light guide:
No of
flashes
Water level below elements. Normal
2
3
Temperature sensor failure (o/c)
4
5
Temperature sensor failure (s/c)
6
MAINTENANCE:
This machine has been designed to give many years of trouble-free service.
The only regular maintenance required is occasional de-scaling.
Descaling Procedure:
• Isolate machine from power supply.
• Isolate machine from water supply.
• ALLOW TO COOL COMPLETELY!
• Drain water from machine.
• Remove all lids.
• Remove as much scale as possible by hand, paying particular attention to level probes
(White plastic with steel tab). Be very careful not to damage any attachments.
• Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
• Thoroughly clean and flush the machine before re-use.
• Follow installation and first-time operation instructions.
CLEANING:
The exterior of these machines may be cleaned with a damp cloth and a light detergent. Do not use
abrasive cloths or creams, as this will spoil the finish of the machine. Do not use a water jet or spray.
NOTE: Beware of accidentally operating the draw off tap or push button when cleaning the front of
the machine.
LIMESCALE:
In common with all water boiler manufacturers, service calls resulting from limescale are not covered
by warranty. Fitting a scale reducer is recommended, especially in hard water areas. This can reduce
the build-up of scale but may not stop it altogether. The frequency that descaling is required depends
on the local water supply; hard water areas need more attention. Descaling of the machine should
ideally be carried out by qualified service personnel.
Symptom
when machine first fills.
Water not heating
Machine not filling
Action required
Check water pressure , if this is OK then call
service agent.
Call service agent
Call service agent
Call service agent
Check water pressure, if OK then call service
agent.