OPERATING INSTRUCTIONS
Timer Function
• Press the TIMER ICON to set the countdown for the unit's main power.
• If the unit is powered OFF, you can press the TIMER ICON to power ON the unit. The emberbed
will glow at the lowest brightness setting unless a different setting was saved in the memory.
• Press the TIMER ICON again to scroll through the timer settings, which are: 30, 1H, 2H, 3H, 4H,
5H, 6H, 7H, 8H, 9H, OF. (30 means 30 minutes, OF means OFF)
• When the timer reaches zero, it will turn OFF the main power and will maintain all the settings in
memory.
HEATER OVERRIDE
The power to the heater can be disengaged to prevent the heater from being accidentally or unintentionally
powering on. This feature is primarily added to help prevent children from powering on the heater when it is
not desired.
• To engage the heater override function press and hold the TEMPERATURE ICON for 10 seconds. The
symbol E3 will display. The heater function is now locked. If the TEMPERATURE ICON is pressed again E3
will appear then fade.The Flame and Timer functions will operate normally. Only the heater and blower are
disengaged.
• To unlock the heater function, press and hold the TEMPERATURE ICON for 10 seconds. The symbol E3 will
display. The heater function is now engaged. By pressing the TEMPERATURE ICON again you will be able
to adjust the heat temperature to your desired temperature.
MEMORY FUNCTION
This unit has a memory function that allows you to turn off the MAIN POWER and retains all the other function
settings (excluding the TIMER function).
• When the unit's main power is OFF, press the POWER ICON once on the insert control panel or on the
remote control to power the unit ON and "wake up" the individual function at the last setting. Press the icon
again to adjust it and press the main POWER ICON on the insert or on the remote control to turn the unit
OFF and save the new setting into memory.
• When the unit is powered ON, the LED readout will show the saved temperature setting. If a temperature
setting was not saved, it will show the flame brightness setting saved in memory. If neither one has a setting
saved to memory, then only the emberbed will glow (as a power light indicator).
• To reset the memory, hold down the main POWER ICON for 10 seconds at any time. When this happens,
the LED readout will blink with two zeros three times and the unit will be shut down.
• Another way to reset the memory is to unplug the unit from the wall.
(CONT'D)
12