Controls And Operating Functions - GE RARWT Manuel Du Propriétaire Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Controls and Operating Functions (RARWT_ _)
1. Mode Button (continued)
HEAT PUMP ONLY – the unit will operate the
heat-pump to raise the RV temperature.
NOTE: if the outdoor ambient drops below 25°F
(-4°C), the heat-pump will be disabled.
FURNACE ONLY – the RV's furnace will operate to
raise the RV temperature. This mode can be disabled
by toggling switch #4 on the thermostat to the "ON"
position.
2. Fan Button
Use this button to toggle between fan speeds and fan modes.
3. Temperature Selection Buttons
Use these buttons to raise and lower the set point.
To change between Fahrenheit (°F) and Celsius (°C), hold both
"TEMP +" and "TEMP –" at the same time for 2 seconds.
49-5000400 Rev. 4
HEAT PUMP + FURNACE
operate the heat-pump to conserve propane.
If the RV temperature drifts further than 3°F
from the setpoint, then the RV's furnace will be
turned ON.
NOTE: the furnace will automatically turn ON,
if the outdoor temperature drops below 25°F
(-4°C) or if the Heat-Pump begins a defrost.
FAN ON – the fan will run even when the set point
has been reached.
AUTO FAN
has been reached.
9

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

RarmcRarec1Rarec2

Table des Matières