EC700 complies with the following
european directives:
- Electromagnetic compatibility
directive, no. 2004/108/EC
(2004/12/15)
- Low voltage directive,
no. 2006/95/EC (2006/12/12)
Device fully protected with double
insulation.
Date / Time
Date and time setting
Top Synchro
Last Top
Date and time of
last sync signal
Information
Name / Ver / SN
Name, software version
and product serial no.
MING charts are not all visible
00 and their configuration
MING charts are not all visible
and their configuration.
MING charts are not all visible :
00 and their configuration
Alarm 1
Mode / Sever
Mode: logical, analog,
combination or deactivated
Alarm 1
Src / Type
Logical alarm setting:
source and type
Alarm 1
Src 1 / Src 2 / Type
Setting of combination
alarm: source 1,
source 2 and type
Alarm 1
Src / Type / Hyst
Setting of analog
alarm: source,
type and hysteresis
Alarm 1
Low / High
Setting of analog
alarm: low or high limit
Idem Alarm 2 to
Alarm 5
4
Descriptions
Auxiliary power supply
AC voltage
DC voltage
Climate
Ambient temperature
Storage temperature
Ambient humidity
Vibration
Vibration
Case
Dimensions
Weight
Protection index of enclosure
Electrical safety
Cat. Install. /degree of pollution
Updating period
Display
RS 485 communication
Digital inputs
Direct voltage
Current
Line length
Pulse duration
Power consumption per input
Internal digital input polarisation power supply
Voltage
Relay output
Set-up (contact setting)
Mechanical strength
AC breaking
DC breaking
RS485 bus communication (JBUS/MODBUS protocol)
Line length
Number of equipment
Modulation speed
Com Modbus
Adress / Mode
Mode and
address setting
Com Modbus
Baudrate / Stop / Parity
Speed, stop and
parity setting
Min
Max
Units
110
400
Vac
120
300
Vdc
-10
55
°C
-20
70
°C
95
% RH
2
G
73 x 90 x 67
mm
215
g
IP51 / IP20
III / 2
1
Sec
0,5
Sec
10
30
Vdc
2
15
mA
1000
m
30
ms
0,4
VA
10
15
Vdc
1 contact (NO, NF)
5
10
cycles
250 Vac/3A
30 Vdc/1A
1200
m
32
9.6K, 19.2K, 38.4Kbds
Modification with
code 1000
Date
Language
Day / Month / Year
English
Day, month,
Language selection
year setting
Hour
Lock Code
Hour / Minute / Second
1000
Hours, minutes,
Password selection,
seconds setting
used for modifying
the config.
Display
Contr./ Backl./ Timeout
Contrast, brightness,
standby setting
Comments
+/-10%, 45/65 Hz,
+/-10%, 5 VA
IEC 60068-2-1/ -2-2
IEC 60068-2-1/ -2-2
IEC 60068-2-30
IEC 60068-2-6 10 to 100 Hz
L x W x H
Front/Case
IEC 61010-1 ed. 3 (300 Vac Ph/N)
Terminal 8 reference
According to IEC 62053-31 Class B
Min. section 1.5 mm² (#16AWG)
max. 16 Hz
Max. 35 mA
2 shielded wires + half duplex
Modification
with code 6825
Maintenance
Factory Cfg / Action
Reset to factory
settings
Maintenance
Input Reset / Src / Act
Input reset
6S 5091.a