RESISTANCE
999.9Ω range max. measurement current ...................... 2.3mA
9999Ω range max. measurement current ....................... 230µA
50.00kΩ range max. measurement current ....................... 23µA
EMI max. Influence (999.9Ω) ........................................ ±0.7Ω
EMI max. Influence (9999Ω) ........................................... ±2Ω
EMI max. Influence (50.00kΩ) ........................................ ±20Ω
RANGE
RESOLUTION
999.9Ω
0.1Ω
9999Ω
1Ω
50.00kΩ
10Ω
FILTER
Cut-off frequency (-3dB) .................................. 7.3Hz to 0.2Hz
Slope ..................................................................... -20dB/Dec.
DIMENSIONS
Dimensions ................................... 96 x 48 x 60 mm (1/8 DIN).
Panel cut-out ....................................................... 92 x 45 mm.
Weight .......................................................................... 150g.
Case material ................................... UL 94 V-0 polycarbonate.
RELAY OUTPUT OPTION
Maximum switching current (resistive load) ......................... 8A
Maximum switching power .............................. 2000VA / 192W
Maximum switching voltage .......................... 400VAC / 125VDC
Contact rating ....................................... 8A @ 250VAC / 24VDC
Contact resistance .............................. ≤ 100mΩ at 6V DC @ 1A
Contact type .................................................................. SPDT
Operate time ............................................................... ≤ 10ms
NOTE:
In case that the outputs are used to drive inductive
loads, it is recommended to add an RC network between
the coil terminals (preferably) or between the relay
contacts, to limit electromagnetic effects and to extend
contacts life.
µDIGI2-P
ACCURACY
±(0.1%rdg + 0.7Ω)
±(0.1%rdg + 6Ω)
±(0.1%rdg + 35Ω)
µDIGI2-P