intake temperature range stated in Chapter 9. No microbiologically impaired water or water of
unknown quality may be used without appropriate disinfection.
If there are official instructions to boil tap water, the filter system must be decommissioned.
When the requirement to boil water comes to an end, the filter cartridge must be replaced and
the connections cleaned.
This fi lter media has been impregnated with silver to preserve the fi lter media and inhibit the
growth of bacteria that may affect the fi lter media. The antimicrobial properties of the treated
fi lter media do not protect users or others against bacteria, viruses, germs, or other disease
organisms.
It is generally recommended to boil tap water for certain groups of people (e.g. people with
weakened immune systems, babies). This also applies to filtered water.
Note for people with kidney disease or dialysis patients: during the filter process, the potassium
content may be increased slightly. If you suffer from kidney disease and/or have to stick to a
special potassium diet, we recommend you consult your doctor beforehand.
MAVEA recommends not to decommission the fi lter system for long periods. If the MAVEA
PURITY C fi lter system is not used for several days, we recommend that the fi lter system be
fl ushed with the volume of water indicated in the table below.
Filter cartridge
PURITY C50 Quell ST
PURITY C150 Quell ST
PURITY C300 Quell ST
PURITY C500 Quell ST
PURITY C1100 Quell ST
PURITY C1000 AC
The filter system must not be opened or dismantled during operation. The filter cartridge must
not be opened.
Production date
Production code fi lter head – example: H 3375 01381
3
Production year, this example: 2013
37
Production week, this example: calendar week 37
5
Production day from Monday (1) to Sunday (7), this example: Friday
01381
Serial identifi cation number
Production code fi lter cartridge – example: B3224350010
3
Production year, this example: 2013
22
Production week, this example: calendar week 22
4
Production day from Monday (1) to Sunday (7), this example: Thursday
35
Internal Identifi cation No. of fi lter medium, this example No. 35
0010
Consecutive number of the fi lter cartridge, this example the tenth cartridge; reset when the day changes
3.5 Technical safety assembly instructions
The appliance in which the fi lter is used must be free of limescale prior to installation.
Protect the filter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open flames.
A stop valve must be installed before the filter system inlet hose.
If the water pressure is higher than 8.6 bar (125 psi), a pressure reducer must be installed in
front of the filter system.
When choosing the material for parts that come into contact with water after the MAVEA fi lter
system, it is important to remember that, due to the process, decarbonised water contains
Flushing volume
from 2 days to 1 week not used
2 liters (0.5 US gallons)
3 liters (0.8 US gallons)
6 liters (1.6 US gallons)
10 liters (2.6 US gallons)
18 liters (4.76 US gallons)
1 liter (0.26 US gallons)
Flushing volume
> 1 week not used
20 liters (5.3 US gallons)
30 liters (7.9 US gallons)
60 liters (15.9 US gallons)
100 liters (26.4 US gallons)
180 liters (47.6 US gallons)
10 liters (2.6 US gallons)
9