Guide de l'utilisateur
Tableau 33: Messages d'erreur du test POST (Suite)
Code
Message d'erreur
d'erreur
8100
Memory Error detected in DIMM group #1
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
8103
Memory Error detected in DIMM group #4.
8104
Memory Error detected in DIMM group #5.
8105
Memory Error detected in DIMM group #6.
8150
NVRAM cleared by jumper.
8151
Password cleared by jumper.
8160
Mismatch Processor speed detected on
Processor 1.
8161
Mismatch Processor speed detected on
Processor 2.
Aucun
Expansion ROM not initialized – PCI Mass
Storage Controller in slot n (n: slot number)
H/W Configuration of BMC is corrupted.
!! Update BMC F/W Configuration by
configuration tool !!
!! Refer to BMC configuration manual !!
Action recommandée
Contactez le service client pour remplacer le module
DIMM du groupe approprié.
Lancez le SETUP pour reconfigurer les paramètres.
Lancez le SETUP pour reconfigurer un mot de passe.
Contactez le service client.
Désactivez l'initialisation de la ROM d'extension du
périphérique optionnel au moyen du SETUP du BIOS
"Utilitaire Setup du
(consultez la section
BIOS" page 66
).
Utilisez ExpressBuilder pour configurer la carte de
gestion distante optionnelle.
263
www.bull.com