The pipes must be positioned on the outlet opening with the male part of each
pipe facing towards the stove. This will stop the creosote/soot caused by
condensation from falling down the pipe and onto the stove (A) facing towards the
stove and (B) facing upwards.
All the pipes, including the one that is in the smoke outlet, will be attached with
two metal screws.
If possible, the stove can be installed in the fireplace under the chimney. Take
the necessary precautions when passing through forged areas, use insulated
double pipes in the cases there is a risk of fire. The pipes will not pass through
attics, roofs, cupboards or any similar hidden area. When it is necessary to pass
through a wall, or a part of a building, the installation will be carried out in
accordance with the NFPA 211 or CAN/CSA-B365 regulations of the Installation
Code for Electrical Appliances for solid fuel burning.

6.2. Chimney:

WARNING: THIS APPLIANCE IS NOT SUITABLE FOR INSTALLATION IN A CHIMNEY
SYSTEM THAT IS SHARED WITH OTHER APPLIANCES.
This product must be connected to a chimney that complies with the requirements
for this type of HT chimneys in the Regulations on UL 103 chimneys or a code-
approved brick chimney with a flue liner.