Install to Fit Your Application
NOTE: Prior to installing, serious consideration must be taken to insure this ventilation system will
operate properly if integrated with any other type of mechanical system, i.e. a forced air system,
or an air handling unit. To insure proper operation & compatibilities of both system, it is required
that the airflows of ventilation systems be balanced, by following the procedures found in this
manual.
Limitations: The product is for residential applications only. Must be installed in accordance with all
national and local regulations, building and safety codes. Flex duct is recommended for connecting to the
ERV/HRV collars to reduce vibration noise.
A
Independent System
This application uses a devoted duct system for the supply and the exhausting of stale air
accumulated in the home.
Honeywell Home recommends installing fresh air grilles in all bedrooms and living areas and to
exhaust the stale air from the bathroom, kitchen, and laundry room.
14
Electrical Requirements:
120 VAC outlet. Ground fault
interrupter (GFI) and dedicated
circuit recommended.
ERV/HRV Ventilation Systems 69-2480EF—19