Testing With Plug Gauge 1.0 Mm Or 2.0 Mm; Service And Maintenance - KNIPEX MicroCrimp 97 52 63 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Owner's Manual 4/8 Indent Crimping Tool MicroCrimp
5

Testing with Plug Gauge 1.0 mm or 2.0 mm

Before starting any job, the basic setting of the pliers (crimp dimension of 1.0 mm or 2.0 mm) needs to be
tested.
Set the adjustment wheel to 1.0 mm or 2.0 mm (basic setting). Please note that the crimp dimension
setting has to take place from a larger value down to a lower value (for example from 1.05 mm to 1.0
mm or from 2.05 mm to 2.0 mm)
Close the plier handles and insert the plug gauge in between the indenters. Please note:
The plug gauge needs to fit snug through the indenters. If this is the case, no deviation exists; the
pliers are ready to be used.
If the plug gauge moves in between the indenters with much clearance or it the plug gauge cannot
be inserted at all, the deviation lies outside of the allowable value. The exact value can be determined
by the precise setting of the adjustment wheel (+/-). If the value lies outside of the allowance, the
manufacturer needs to be informed.
ATTENTION!
The adjustment of the crimp tool should only be executed by authorized and qualified personnel,
because improper alignment settings may lead to faulty crimping connections.
The following plug gauges are to be used:
Art. No.
Plug Gauge Size
97 52 63
1 mm
97 52 65
2 mm
97 52 65 A
2 mm
6

Service and Maintenance

The pliers must be in clean and proper working condition before starting any job. Please remove any
remains from the crimping procedure from the indenters and locators of the pliers. Please note that all
bolts are secured by locking rings.
All repairs need to be performed by the manufacturer or an authorized dealer.
Rev.: 2016-06-13
EN
6 / 6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Microcrimp 97 52 65Microcrimp 97 52 65 a

Table des Matières