TECHNICAL SPECIFICATIONS
UNITO INFINITY Smart Water System
Dispensing water types :
Ÿ
water, Boiling water, Chilled water, Cold/Hot tap water.
BTank capacity:
Ÿ
water, 2 Liters cold water.
Boiling time:
Ÿ
Cooling time:
Ÿ
Min./Max. mains pressure:
Ÿ
System max. safety pressure:
Ÿ
Max. hot water temperature:
Ÿ
Operation:
Ÿ
Power supply :
Ÿ
Max. power consumption:
Ÿ
Standby power consumption :
Ÿ
Safety features:
Maximum temperature fuse, Safety valve(including
Ÿ
pressure relief valve , a built-in one direction valve & on/off valve).
Dimensions:
Ÿ
Weight:
Ÿ
Flow rate:
Ÿ
Max. water hardness :
Ÿ
CARE AND MAINTENANCE
Regular maintenance of the UNITO INFINITY Smart Water
System is required to prevent damage or downtime. Service
should be performed by qualified and certified personnel only.
Warning: Disconnect the power supply from the UNITO INFINITY
Smart Water System before maintaining the unit。
Keep the UNITO INFINITY Smart Water System in a dry,
Ÿ
clean space. Minimize exposure to dust. Power button or
other controls should never be wet.
If the unit becomes wet, immediately shut it down. Wait for the
Ÿ
unit to completely dry before turning it on again.
Clean exterior surfaces of the unit with a soft, lint-free cloth.
Ÿ
Never use alcohol, paint thinner, benzene or other solvents to
clean this unit. Never use an abrasive material such as a
brush or scouring pad to clean surfaces.
Always test your cleaning solution on an inconspicuous area
Ÿ
before applying to the entire surface.
Wipe surfaces clean after applying cleaner.
Ÿ
Never expose the unit to vibration.
Ÿ
Make sure that all cabin ventilation outlets are always free
Ÿ
and clear.
In the event of mechanical/power failure or damage, do not
Ÿ
attempt to repair the system unit or wires. Call a certified
technician.
If the UNITO INFINITY Smart Water System requires service,
Ÿ
please consult a certified dealer. Unauthorized service may
void the warranty.
Close/open the system valve and safety valve every 6
Ÿ
months.
Clean aerator once a year.
Ÿ
Sparkling water, Ambient
850 cc Sparkling. Boiling water: 4.4 Liter,
15 minutes (from 25°C to 100°C).
30 minutes (from 25°C to 3°C).
2/5 bar (200/500 kPa).
8 bar (800 kPa).
Operation via Electronic control knob, handle.
220~240VAC, 50HZ.
485 x 250 x 484 mm.
2 L/min @3bar.
TROUBLESHOOTING
Read and follow the assembly instructions. If the UNITO
INFINITY Smart Water System is not functioning, please check
troubleshooting table. If the water system is still not working
properly, disconnect power supply and contact authorized
UNITO customer service center for assistance. When calling for
assistance, please provide your product model and serial
number.
Symptom
No water
100°C.
owing, the
water is
owing too
slow
1650 W.
2.5 W.
The water is
27 KG.
sputtering or
is irregular
10° dH.
Air/water
dripping from
the faucet
while
preparing
soda
No boiling
water
No Chilled
water
No Soda or
Soda is weak
27
Possible Cause
Solution
- Main water supply valve
- Turn on the main water
is turned off.
supply valve.
- The water system is not
- Connect all the cable
connected properly.
and hose correctly.
- Hoses are bended.
- straighten the hoses.
- There is limescale or dirt
- Clean/replace the
in the aerator.
aerator.
- check the filter
- Filter wrong installation
connection.
- Check the water
pressure. It should be
above 1.0 bar. Check a
- There is no or too little
different tap. If the
water pressure.
pressure is also low
there, check the mains
water tap and contact
your water supplier.
Normal behavior due to
- High pressure in CO2
high pressure, normally
cylinder.
when using a new
cylinder.
- The boiler is turned off or
- Connect to power
not connected to power
supply.
supply wall socket.
- Safety valve or main
- Turn on the Safety valve
water supply valve is
or main water supply
turned off.
valve.
- Faulty Safety valve(cut-
- Contact UNITO
off).
customer service.
- Follow page 14 step A
- the boiler is not activated
to C
- The Chiller is powered
- Connect to power
off or not connected to
supply.
power supply wall socket.
- Faulty function of chiller.
- Restart the system.
- Faulty
- Contact UNITO
cables/hoses/control knob.
customer service.
The CO2 cylinder not
- Install the CO2 cylinder
installed or not installed
properly.
properly.
- Replace with a new
- CO2 cylinder is empty.
CO2 cylinder.
- Change to a higher
- Soda intensity setting is
intensity level soda
low.
through the UNITO
mobile APP.